期刊文献+

制备一次性碳质膜电极的新方法 被引量:5

A novel method for fabricating disposable carbon film electrode
下载PDF
导出
摘要 报道了利用一种钢质模具在PVC底板上制作一次性碳质膜电极的新方法,并在此基础上探讨了影响该膜电极制备及其电化学特性的一些物理因素和化学因素.研究结果表明,用此方法制作的电极易于对其进行修饰,并用其做循环伏安扫描和电化学发光研究,表现出较好的电化学可逆性(ipa/ipc=1 16)、电化学发光重现性(RSD=1 5%,cLu=2.0×10-6mol/L,n=8)以及较好的灵敏度. A novel method for fabricating disposable carbon film electrode by using a steel mould in PVC soleplate is put forward . Based on this idea, some physical and chemical factors, which have the effect on preparation and electrochemical traits of electrodes, are discussed. The results show that electrodes prepared in this method, are easy to be modified, and cyclic Voltammetry scanning experiments and electro-chemiluminescence study are done with better electrochemical reversibility(i_(pa)/i_(pc)=116), and better electro-chemiluminescence reproducibility(RSD=1.5%, c_(Lu)=2.0×10^(-6)mol/L,n=8)and sensitivity.
出处 《陕西师范大学学报(自然科学版)》 CAS CSCD 北大核心 2005年第1期75-77,共3页 Journal of Shaanxi Normal University:Natural Science Edition
基金 陕西省自然科学基金资助项目(691103)
关键词 碳质膜电极 丝网印刷技术 PVC底板 钢质模具 carbon film electrode screen printed technology PVC soleplate steel mould
  • 相关文献

参考文献9

  • 1张贤珍,刘旭辉,莫志宏.丝印电化学传感器及其应用研究进展[J].现代科学仪器,2002,19(4):46-50. 被引量:10
  • 2Wang J Rivas, Cai G, Palecek E Nielsem, et al. DNA electrochemical biosensors for environmental monitoring [J]. A Review Analytical Chemica Acta, 1997, 347(1-2): 1~8. 被引量:1
  • 3Zhang S, Wright G, Yang Y. Materials and techniques for electrochemical biosensor design and construction [J].Biosensors and Bioelectronics, 2000, 15(5-6): 273~282. 被引量:1
  • 4Stephen A Wring, John P Hart. Chemically modified,screen-printed carbon electrodes [J]. Analyst, 1992, 117:1281~1 286. 被引量:1
  • 5John P Hart, Stephen A Wring. Recent developments in the design and application of screen-printed electrochemical sensors for biomedical, environmental and industrial analyses [J]. Trends in Analytical Chemistry, 1997,16(2): 89~103. 被引量:1
  • 6Honeychurch K C, Hart J P, Pritchard P R J, et al.Development of an electrochemical assay for 2, 6 -dinitrotoluene, based on a screen-printed carbon electrode, and its potential application in bioanalysis,occupational and public health [J]. Biosensors and Bioelectronics, 2003, 19(4): 305~312. 被引量:1
  • 7Nunes G S, Grabaric B S, Diaz-Cruz J M. Evaluation of a highly sensitive amperometric biosensor with low cholinesterase charge immobilized on a chemically modified carbon paste electrode for trace determination of carbamates in fruit, vegetable and water samples [J].Analytica Chemica Acta, 1999, 399(1-2): 37~49. 被引量:1
  • 8Regan O, Tina M, Pravda Miloslav, et al. Development of a disposable immunosensor for the detection of human heart fatty-acid binding protein in human whole blood using screen-printed carbon electrodes[J]. Talant, 2002,57(3): 501~510. 被引量:1
  • 9Artigas J, Jimenez C, Lemos, et al. Development of a screen-printed thick-film nitrate sensor based on a graphiteepoxy composite for agricultural applications [J]. Sensors and Actuators B, 2003, 88(3): 337~344. 被引量:1