摘要
提出用浓H2SO4从大气飘尘样品的环己烧提取液中一次萃取后,用同步荧光光谱测定苯并(a)芘的方法。选用△λ为20nm时可获最佳效果,用浓硫酸萃取的时间仅1min,苯并(a)芘在浓硫酸相中1h内稳定,样品加标的回收率为85%,其它多环芳烃化合物在530—600nm的测定波长范围不干扰苯并(a)芘的测定。用乙酰化滤纸层析-荧光分光光度的统一方法作为对比对实际样品进行了测定,结果与后者的偏差在±15%以内,分析周期可缩短24h。
A rapid and effective method for detecting benzo(a) pyrene in airborne particulates was developed, in which benzo (a) pyrene was extracted in an one minute step with concentrated sulfuric acid from a cyclohexane extracted solution from the airborne particulates, and then determined with a synchronous fluorescent speetrometry. The best results were obtained at ac of 20urn.Benzo (a) pyrene in the concentrated sulfuric acid phase was stable within 1 hour.The recovery was found to be 85% for 0. 10 ig of benzo(a)pyrene standard. No interference with other polynuclear aromatic hydrocarbons was found in the range of 530-- 600 urn of synchronous fluorescent spectra. For a comparison, the samples were also determined by using the unified method of acetylized paper TLC/ fluorescent photospectrometry,with the results in a variance of 15% between both methods. The analytical cycle for the present method can shorten by 1 hour
出处
《环境科学》
CAS
CSSCI
CSCD
北大核心
1994年第3期65-67,共3页
Environmental Science
基金
北京市自然科学基金
关键词
苯并(A)芘
同步荧光光谱
大气飘尘
benzo (a ) pyrene, synchronous fluorescent spectrometry, extraction, airborne particulates.