在电容器未经预充电和预充电两种起始条件下,对绝缘电阻的测量值进行瞬态分析,定量地导出两种起始条件下测量值与仪器内阻、电容器固有特性之间的关系。为分析测量结果和制定标准提供依据。
Transient analysis of measured values of insulation resistance of capacitors with and without precharging is made, dependences of the measured values under obove-mentioned two initial conditions on internal resistance of the instrument and intrinsic characteristics of the capacitors are deduced quantitatively.Obtained results provide basis for analyzing the measured values and formulating criteria.
出处
《电子元件与材料》
CAS
CSCD
1994年第6期50-53,共4页
Electronic Components And Materials
关键词
电容器
绝缘电阻
测量
定量分析
measured values
intrinsic characteristic
measurement duration
initial condition of measurement