摘要 介绍了污水处理厂化验室用重铬酸钾法同时测定污水处理前和处理后的CODCr浓度时,重铬酸钾溶液的浓度改为0.0500mol/L,硫酸亚铁铵溶液的浓度改为0.02mol/L,不但不会影响测定结果,还能有效地降低化验成本,节约工作时间,同时减少化验室废水对环境造成的二次污染。 It is introduced that when the CODCr concentrations both before and after the treatment are determined by using potassium dichromate method in the wastewater treatment plant laboratory, the concentration of potassium dichromate solution is adjusted to 0.050 0 mol/L and the concentration of ammonium irons(Ⅱ) sulfate hexahydrate solution to 0.02 mol/L. This will not influence the determination result, but can reduce the essay cost, save working hours and reduce the secondary environmental pollution caused by the wastewater from the laboratory.
作者 匡云霞
出处 《工业水处理》 CAS CSCD 北大核心 2005年第1期52-53,共2页 Industrial Water Treatment
关键词 污水处理厂 化学耗氧量 重铬酸钾 硫酸亚铁铵 wastewater treatment plant chemical oxygen demand potassium dichromate ammonium irons(Ⅱ) sulfate hexahydrate
  • 相关文献

参考文献3

  • 1水和废水监测分析方法编委会.水和废水监测分析方法(第4版)[M].北京:中国环境科学出版社,2002.458. 被引量:4
  • 2GB 11914-1989.水质-化学需氧量的测定,重铬酸钾法[S].[S].,.. 被引量:1
  • 3CJJ60-1994.城市污水处理厂运行、维护及其它安全技术规程[S].[S].,.. 被引量:1