期刊文献+

恒温平台石墨炉法测定人血白蛋白制剂中的铝 被引量:1

Determination of Aluminium in Human Serum albumin by stable temperature platform graphite furnace
下载PDF
导出
摘要 本文建立了测定人血清白蛋白中铝的有效方法。样品用0.5硝酸直接稀释后使用标准加入法测定铝含量。应用两步灰化法有效的降低了有机物引起的干扰而且容许高达1500℃的灰化温度亦不会造成铝的丢失。同一样品使用标准曲线法和牛血清参考物(wbs)的分析确认了该法的可靠性。 A valid method for analyzing the aluminium in human serum albumin (HSA) is developed. By using standard addition method after diluting the sample with 0.5%HNO3 directly, the aluminium in HSA was measured, using pyrolytically coated transverse heating graphite tube with platform equipped in TAS-990 atomic absorption spectrophotometer that is produced by Beijing Purkinje general instrument Co., Ltd. Two ashing stages in the heating program was proved to be effective in eliminating the interferences aroused by the organic compounds and the aluminium will not losing when ashing temperature is up to 1500℃. This method was ensured by analyzing the sample with calibration curve and by analyzing the aluminium in bovine serum reference material (GBW0912).
出处 《生命科学仪器》 2004年第6期48-49,共2页 Life Science Instruments
关键词 人血白蛋白 制剂 牛血清 参考物 人血清白蛋白 有效方法 测定 炉法 硝酸 灰化温度 Albumin, Aluminium, Transverse heating graphite tube, Platform, Standard Addition method
  • 相关文献

参考文献1

  • 1[3]Leung. F. Y, Henderson, A.R. At. Spectrosc., 4,1-4, 1983. 被引量:1

同被引文献6