期刊文献+

长期遥控监测动物血压法的建立及其在高血压鼠中的应用 被引量:3

Establishment of a radio-telemetry method for long-term continuous blood pressure recording in conscious animal and its application in spontaneously hypertensive rat
下载PDF
导出
摘要 目的:建立一个连续长期遥控监测清醒动物血压的方法并能连接传统血压测定系统.方法:将无线电遥测装置经腹腔植入大鼠腹主动脉,血压信号通过桥装置记录,使用自编软件计算机处理.在非高血压WKY大鼠中建立了连续遥控监测血压方法后,观察一组8只清醒高血压大鼠术后2~17周的每周连续24 h的血压.结果:本实验连续遥控监测清醒动物24 h血压期间重复测得的大鼠每周连续24 h血压经统计学检验无显著性差异;收缩压和舒张压总平均值分别为:170±2和115±1mmHg.结论:成功建立了连续长期重复遥控监测清醒高血压大鼠血压的方法. Objective: To establish a radio-telemetry system for long-term continuous blood pressure (BP) recording in conscious animal, bridging for traditional BP record method. Methods: A transmitter was implanted into the abdominal aorta of rat. 24h BP signal was recorded using Maclab hardware and analyzed by a newly written software. It was established in WKY rat and applied in spontaneously hypertensive rat (SHR). 24h BP of SHRs (n = 8) was measured from 2 to 17 weeks post implantation. Results: The system was successfully established. There was no significant difference in BP between weekly monitoring periods. The total average BP over the monitoring period was 170 ±2 (SBP) and 115 ±1 (DBP) mmHg. Conclusion: The radio-telemetry system for long-term continuous BP recording in conscious SHR is successfully established, bridging for traditional BP recording method.
出处 《心血管康复医学杂志》 CAS 2004年第6期520-521,共2页 Chinese Journal of Cardiovascular Rehabilitation Medicine
关键词 高血压 大鼠 监测血压 动物血 清醒 血压测定 经腹 腹主动脉 植入 腹腔 A radio-telemetry system Long-term continuous blood pressure Hypertension
  • 相关文献

参考文献3

  • 1[1]Brockway BP, Mills PA. A new method for continuous chronic measurement and recording of BP, heart rate and activity in the rat via radio-telemetry [J]. Clin Exp Hypertens A, 1991, 13: 885-895. 被引量:1
  • 2[2]Van den Buuse M. Circadian rhythms of blood pressure, heart rate, and locomotor activity in spontaneously hypertensive rats as measured with radio-telemetry [J]. Physiol Behav, 1994, 55:783-787. 被引量:1
  • 3[3]Whitesall SE, Hoff JB. Comparison of Simultaneous Measurement of Mouse SBP by Radiotelemetry and Tail-cuff Methods [J]. Am J Physiol Heart Circ Physiol, 2004; 286: H2408. 被引量:1