期刊文献+

发电机内冷水空心导线的腐蚀速率分析

ANALYSIS OF HOLLOW CORE CONOUCTOR CORROSION RATE CAUSED BY INNER-COOLING WATER IN GENERATORS
下载PDF
导出
摘要 针对发电机空心导线腐蚀问题 ,提出了腐蚀速率的计算公式 ,即采用检测内冷水中铜离子浓度的方法推算出空心铜导线的腐蚀速率 ,并给出计算实例。计算结果显示 ,内冷水铜离子含量≤ 4 0 μg/L时 ,对应的腐蚀速率仅为 1 .1 2 8× 1 0 - 3 mm/a 。 Directing against the problem of hollow core condutor corrosion in generators. a formula for calcurating the corrsion rate.i.e.the corrosion rate of hollow core conductor is calculated by using the method of detecting copper ion concentration in the inner-cooling water, has been put forward, and real calculation exmple being given. Result of calculation shows that, when the copper ion content in inner-cooling water≤40 Mg/L, the corresponding corrosion rate only to be 1.128×mm/a, satisfying the related regulations.
出处 《热力发电》 CAS 北大核心 2004年第12期62-63,65,共3页 Thermal Power Generation
关键词 发电机 内冷水 空心导线 腐蚀速率 计算方法 generator inner-cooling water hollow core conductor corrsion rate
  • 相关文献

参考文献1

  • 1[1]张警生.发电机冷却介质[M].中国电力出版社,1998. 被引量:1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部