期刊文献+

电抗移相相复励发电机无功不足的原因分析及处理措施

The causation analysis and the disposal measures on idle deficiencyin reactance phase shift phase compounded self excitation generators
下载PDF
导出
摘要  开平市在20世纪70年代所建的小水电站低压机组很大一部分是采用电抗移相相复励磁,这种励磁装置具有线路简单、可靠性高、维护工作量小、无功调节范围宽和自励恒压特性较好等优点。但当使用不正确时,会出现发电机不能发出额定无功的毛病,针对该装置几种常见的发不足无功情况加以分析。 A great part of the low-pressure sets in midget water power stations built in 1970's in kaiping city are adopting reactance phase shift phase compounded self excitation,the advantage of the excitation equipments are straightforward circuitry、high dependability、little maintenance work、broad range idle adjustment and excellent self-excitation constant voltage characteristic. The generators can not give off rating idle when in improper usage. The article is aimed at analyze on some kinds of common defects of idle deficiency.
作者 周玉绪
出处 《水利科技与经济》 2004年第5期310-311,共2页 Water Conservancy Science and Technology and Economy
关键词 电抗 移相 相复励 无功 水电站低压机组 reactance phase shift phase compounded self excitation idle causation measure
  • 相关文献

参考文献2

  • 1王定一主编..水电站控制技术 上[M].武汉:华中理工大学出版社,1988:212.
  • 2[2]王铁汉. 水轮发电机组自动化和运行[M].北京:电力工业出版社,1981.106-121. 被引量:1