摘要 A high-precision digital measuring scheme for half-wave voltage of Y-tap multiple integrated optical circuits is proposed. This scheme is based on Sagnac interferometer modulated with digital step waveform whose frequency is half of eigen frequency of the interferometer. The technology and measuring precision are discussed. An experimental setup is made and the temperature-dependences of half-wave voltage of two samples are studied. Analysis and experimental study prove that this scheme is convenient and accurate. A high-precision digital measuring scheme for half-wave voltage of Y-tap multiple integrated optical circuits is proposed. This scheme is based on Sagnac interferometer modulated with digital step waveform whose frequency is half of eigen frequency of the interferometer. The technology and measuring precision are discussed. An experimental setup is made and the temperature-dependences of half-wave voltage of two samples are studied. Analysis and experimental study prove that this scheme is convenient and accurate.
出处 《Chinese Optics Letters》 SCIE EI CAS CSCD 2004年第11期640-642,共3页 中国光学快报(英文版)
基金 ThisworkwassupportedbytheNationalNaturalSci-enceFoundationofChinaunderGrantNo.60207002
关键词 GYROSCOPES Integrated circuits INTERFEROMETERS Gyroscopes Integrated circuits Interferometers