期刊文献+

两种荧光显微成像系统采集细胞器探针荧光图像的对比研究 被引量:3

Comparison of two fluorescence microimaging system collecting fluorescence images of organelle probes
下载PDF
导出
摘要 目的 :应用荧光显微数码成像系统和共聚焦荧光显微成像系统采集细胞器探针图像的对比研究。方法 :传代培养内皮细胞 ,将四种细胞器探针与细胞共同孵育不同时间。采用荧光显微镜、计算机及高分辨率数码CCD组成的荧光显微数码成像系统采集四种细胞器探针的荧光图像。同时应用激光共聚焦显微镜采集图像进行对比。结果 :两种系统均可采集到细胞器荧光探针的图像 ;荧光显微数码成像系统采集的图像的特点为分辨率高 ,速度快 ,对细胞器的损伤小。结论 :荧光显微数码成像系统在细胞器探针的荧光检测定位研究中准确可靠。 Objective:Applying two fluorescence microimaging system to collect fluorescence images of organelle probes. Methods:Endothelial cells were subcultured and incubated with four organelle probes for various time. Fluorescence microscope,computer and high-resolution digital CCD were applied to collect fluorescence images of four organelle probes. At the same time Laser Scanning Confocal Microscope was used to collect images as a comparison. Results:The two fluorescence microimaging system both can collect fluorescence images of organelle probes. The details of fluorescence images collected by high-resolution digital CCD are clear and faster. Conclusions:Fluorescence microscope and digital CCD collectig fluorescence images of organelle probes is reliable and practical.
出处 《军医进修学院学报》 CAS 2004年第6期434-435,共2页 Academic Journal of Pla Postgraduate Medical School
  • 相关文献

参考文献4

  • 1White JG,Amos WB.Confocal microscopy comes of age[J].Nature,1987,328:183-184. 被引量:2
  • 2Paddock SW.Principles and practices of laser scanning confocal microscopy[J].Mol Biotechnol,2000,16:127-149. 被引量:2
  • 3Paddock SW.Confocal laser scanning microscopy[J].Biotechniques,1999,27(5):992-996. 被引量:2
  • 4Sando JJ,Maurer MC,Bolen EJ.Role of cofacors in protein kinase C activation[J].Cellular Singlling,1992,4:595-609. 被引量:2

同被引文献20

  • 1吴希如 张一 等.胚鼠大脑皮层神经元的体外原代分离单层培养方法[J].北京医学院学报,1983,15(3):169-172. 被引量:12
  • 2Teruel MN, Chen W, Persechini A, et al. Differential codes for free Ca^2+ calmodulin signals in nucleus and cytosol[J]. Curr Biol, 2000,10:86-94. 被引量:1
  • 3Fall C, Bennetl JJ. Visualization of cyclosporin A and Ca^2+ sensitive cyclical mitochondrial depolarization in cell culture[J1. Biochim Biophys Acta, 1999, 1410:77-84. 被引量:1
  • 4Katz E, Verbitaky M, Rothlin C, et al. High calcium permeability and calcium block of the α 9 nicotinic acetylcholine receptor[J]. Hear Res, 2000,141:117-128. 被引量:1
  • 5Liu Z, Yang Y, Silverira DC, et al. Consequences of recurrent seizures during early brain development [ J ]. Neuroscience, 1999,92 : 1443-1454. 被引量:1
  • 6Takahashi A, Camach OP, Lechleiter JD, et al. Measurement of intracellular calcium [ J ]. Physiol Rev, 1999,79:1089-1125. 被引量:1
  • 7Petroll W M, Jester J V, Lavanagh H D. In vivo confocal imaging;general principle and applications[J]. Scanning, 1994,16(3):131. 被引量:1
  • 8Fall C, Bennetl JJ. Visualization of cyclosporion A and Ca^2+ sensitive cyclical mitochondrial depolarization in cell culture[J].Biochim Biophys Acta, 1999, 1410(1):77-84. 被引量:1
  • 9Teruel M N, Chen W, Persechini A, et al. Differential codesfor free Ca^2+ -calmodulin signals in nucleus and cytosol[J].Curr Biol, 2000,10(2) : 86-94. 被引量:1
  • 10Katz E, Verbitaky M, Rothlin C, et al. High calcium permeability and calcium block of the a9 nicotinic acetylcholine receptor[J]. Hear Res, 2000,141:117-128. 被引量:1

引证文献3

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部