以实践为基础 ,对测量汽包水位中使用的双室平衡容器的工作原理与特性作了详细介绍。重点讨论了补偿系统的建立方法与步骤 ,同时指出了应用中的常见错误并提出了解决方案。
On the basis of practicing, the operational principle and features of dual condensation chamber used for drum water level measurement are presented in detail. The method and procedures of establishing the compensation system are discussed emphatically. Also the common errors in application and their solutions are stated.