摘要
结合工程实例,比较低温送风和常规送风方式下冰畜冷空调与常规空调的经济性,指出了采用低温送风技术有助于缩短投资回收期,降低了运行费用,并借助CFD手段,探讨了低温送风时房间气流组织,温度场分布。
Based on a real case, the technical and economical analysis of an ice storage air -conditioning system by using cold air distribution and normal air supply method is carried out in this paper. The results indicate that the application of cold air distribution will reduce the callback - period of first costand cut down the maintain cost as well. With the help of CFD, this paper also discusses the temperature and velocity field of cold air distribution system.
出处
《制冷与空调》
2004年第4期80-84,共5页
Refrigeration and Air-Conditioning
关键词
冰蓄冷空调
低温送风
送风方式
经济性分析
ice storage, way of air distribution, analysis of economic, cold air distribution