砖混结构在我国民用住宅中普遍使用,但砖混结构房屋中出现的现浇楼板斜裂缝问题也引起各方的关注。结合工程实例,在假定结构处于弹性工作范围内,混凝土不开裂的前提下,对现浇楼板的斜裂缝进行了有限元分析,并提出一些预防裂缝的建议。
Brick-and-concrete construction has been popularly used in residential houses in China, but cast-in-situ floor oblique crack in brick-and-concrete construction building has attracted attention from all aspects. Finite element analysis on cast-in-situ floor oblique crack in brick-and-concrete construction building has been made combined with engineering practice assuming the structure under elastic working range and presupposition of concrete without crack. Suggestions have been made to prevent crack.