期刊文献+

利用电导技术提高阀控式蓄电池维护质量 被引量:3

Improving the maintenance quality of Valve-Regulated Lead-Acid batterywith conductance technique
下载PDF
导出
摘要 随着通信无人值守站的增多,阀控式铅酸蓄电池的用量也大大增加,传统的维护方式不仅耗费大量的人力、物力,而且也不能及时、全面地了解蓄电池的应用情况。利用基于电导技术开发的蓄电池电导测试仪来巡检蓄电池,不仅能够快速、准确地判断蓄电池的使用状况,还能利用其专用的分析、管理软件建立蓄电池档案,全面地了解所辖区域蓄电池的使用状况,从而真正做到对蓄电池科学有效的管理。 With the duty-free communication stations increasing, Valve-Regulated Lead-Acid (VRLA) batteries are largely used. The traditional maintenance mode is not only a waste of manpower and material resources but also being incapable of understanding the situation of the applications of VRLA batteries completely and in time. By using the conductance-based VRLA testing meter to check the batteries can judge the operation situation quickly and exactly. At the same time, the battery operating data files can be set up by its special analysis and management software. So the operation situation of the VRLA battery in the administrating area can be acquired completely. The management of the batteries can be realized scientifically and effectively.
出处 《电力系统通信》 2004年第11期7-8,64,共3页 Telecommunications for Electric Power System
关键词 阀控式铅酸蓄电池 阀控式 电导测试 用电 判断 通信 无人值守 技术 管理软件 增加 Valve-Regulated Lead-Acid (VRLA) battery conductance technique operating and maintenance