指出了厂用电事故下的成功切换对电厂安全生产的重要意义,分析了目前厂用电切换方法存在的不足。提出了基于模糊推理的快速切换原理,利用模糊推理的方法,提高了串联事故切换的成功率。
The successful station service supply change-over on the power station bus in the fault state is very important to the safety production. The shortage of current change-over methods is analyzed, and a novel method based on fuzzy theorization is also presented, which can be used to enhance the ratio of successful change-over.