以100kW/18kHz的实验样机为例,分析并研究了感应热水机组进行电-热-水热交换过程中器件的电损耗及工程估算方法,设计出了电损耗转换为水热的技术方案,实现了电感应热水机组电-水热转换效率的提高。
This article analyses the electric ullage of the parts in inductive hot-water heaters by using the 100kW/18kHz experimental device as the example, which was generated in the process of electro-thermal conversion and thermo-hot water heating conversion. On the basis of engineering-estimated methods, a new device which could be used to convert the electric ullage to hot water by water cooling and a new way to improve the efficiency of thermo-hot water heating conversion come into being.
出处
《陕西科技大学学报(自然科学版)》
2004年第6期88-92,共5页
Journal of Shaanxi University of Science & Technology
基金
陕西省教育厅产业化培育项目(编号:26-02JC26)资助
关键词
电感应热水机组
电损耗
电—水热转换效率
inductive hot-water heaters
electric ullage
efficiency of thermo-hot water heating conversion