摘要 目的 :探讨影响数字X线照片影像质量的相关因素 ,提高数字X线照片影像质量。方法 :通过分析计算机X线摄影 (CR)与直接数字X线摄影 (DR)所产生的数字X线照片影像质量相关因素 :曝光量与自动曝光控制 (AEC)的使用 ;DR、CR主机 (扫描仪 )及图像读取工作站 ;影像板 (IP)因素 ;图像后处理工作站功能 ;激光打印机等。针对数字X线照片成像的各个环节加以控制。结果 :获得优质数字X线照片影像必需做到 :选择合适的曝光条件并合理使用AEC ;掌握DR主机、CR扫描仪及图像读取工作站的性能特点 ;保证IP质量及定期清洗保养IP ;充分了解并利用好图像后处理工作站的功能 ;正确设置配套激光打印机参数。结论 :了解影响数字X线照片影像影像质量的相关因素 ,充分发挥数字X线照片影像图像的后处理优势 ,可以明显提高数字X线照片影像图像的质控水平。 Objective:To investigate the related factor that impact the quality of digital X-ray plain film,and improve the quality.Methods:To analyze the related factor that impact the quality of digital X-ray plain film in the computed radiography(CR)and direct digital radiography(DR),such as: the exposure doses and usage of automatic exposure control(AEC); the mainframe of CR or DR and its image-taking workstations;imaging plate(IP);the function of the image processing workstations;laser printer,etc.Results:To acquire the fine quality digital X-ray plain film,it is essential to choose the fit exposed doses, use AEC reasonably, understand the characteristics of the mainframe of CR or DR and its image-taking workstations, guarantee the quality of IP,maintain the IP regularly,understand and make full use of the image processing workstations,set the parameters of the laser printer correctly.Conclusion:To know the related factor that impact the quality of digital X-ray plain film,take the full advantage of the image processing function,it could be further promoted the level of quality control of digital X-ray plain film.
出处 《医学影像学杂志》 2004年第9期748-750,共3页 Journal of Medical Imaging
关键词 质量控制 图像处理 计算机辅助 放射摄影术 Quality control Image processing,computed-assisted Radiography
  • 相关文献

参考文献4

二级参考文献8

  • 1全国放射科QA,QC学术研讨会纪要[J].中华放射学杂志,1993,27(2):134-138. 被引量:134
  • 2Chotas HG, Dobbins JT 3rd, Ravin CE. Principles of digital radiography with large-area, electronically readable detectors : a review of the basics. Radiology, 1999, 210: 595-599. 被引量:1
  • 3Chotas HG, Floyd CE, Ravin CE.Technical evalution of a digital chest radiography system that uses a selenium detector. Radiology, 1995,195:264-270. 被引量:1
  • 4Woodard PK, Slone RM, Gierada DS, et al. Chest radiography :depiction of normal anatomy and pathologic structures with selenium-based digital radiography versus conventional screen-film radiography. Radiology, 1997,203:197-201. 被引量:1
  • 5Garmer M, Hennig SP, Jager H, et al. Digital radiography versus conventional radiography in chest imaging :diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study. AJR,2000,174:75-80. 被引量:1
  • 6Bernhardt TM, Otto D, Reichel G, et al. Detection of simulated interstitial lung disease and catheters with selenium,storage phosphor, and film-based radiography. Radiology,1999,213:445-454. 被引量:1
  • 7Chotas HG,Floyd CE Jr,Ravin CE.Memory artifact related to selenium-based digital radiography systems.Radiology,1997,203:881-883. 被引量:1
  • 8Cesar LJ,Schueler BA,Zink FE,et al.Artefacts found in computed radiography(Review).Br J Radiol,2001,74:195-202. 被引量:1