期刊文献+

表面活性剂增敏I_3间接光度法测定硅灰石和水中锰 被引量:1

Determination of Manganese in Silica and Water with I_3-Indirect Spectrophotometry by Using Surface Active Agent for Increasing Sensitivity
下载PDF
导出
摘要 提出了用铋酸钠氧化Mn^(2+)为MnO_4^-,MnO_4^-氧化I^-为I_2进而生成I_3^-,在350nm处测I_3^-吸光度,间接测定锰含量方法。加入TPC有明显增敏和掩蔽作用,灵敏度和选择性较好。实测硅灰石中锰含量,相对标准偏差(RSD)为1.5%;实测天然水中锰含量,RSD为1.9%~4.9%,回收率为94.2%~106.2% In this paper the method that the concentration of Mn was indirectly determined was set up. Here Mn^(2+) was oxided by Na_2BiO_3 to MnO_4^- and I^- was oxided by MnO_4^- to I_2 then to I_3^-, the absorption of I_3^- was determined at 350nm. Adding TPC evidently increases sensitivity and has sheltering. Sensitivity and selectity are better. Mn in silica was actually determined, relative deviation (RSD) is 1.5%. Mn in water was actually determined, RSD is 1.9%~4.9%, the recovery is 94.2%~106.2%.
出处 《河北化工》 1993年第4期60-62,共3页 Hebei Chemical Industry
关键词 间接光度法 铋酸钠 碘酸根 I_3- manganese indirecs spectrophotometry sodium bismuthate
  • 相关文献

同被引文献5

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部