摘要
介绍了减温减压器的安全稳定性 ,从设计安装、运行维护、设备结构形式等方面进行了论述 ,对减温减压器运行中的缺陷问题进行了分析处理 。
The safety and stability of temperature-decreased pressure reducer are introduced and discussed from design, installation, operation, maintenance and other aspects; at the same according to the problems encountered in operation analysis is made. In addition corresponding treatment measures are proposed.
出处
《山西建筑》
2004年第14期121-122,共2页
Shanxi Architecture
关键词
减温减压器
安全稳定性
原因分析
处理方法
temperature-decreased pressure reducer, safety and stability, causes analysis, treatment measure