75t/hCFB锅炉增压风机运行方式优化改造 被引量:3

Optimal Transform of Operational Mode of 75t/h CFB Boiler Pressurized-Fan
下载PDF
导出
摘要 通过对各种技术改造方案进行比较分析 ,将 2台 75t/h循环流化床 (CFB)锅炉增压风机的运行方式进行优化改造 ,90kW增压风机由长期恒速运行转变为联锁备用自投状态 ,大大降低了厂用电耗 ,取得了良好的经济效果。 Through comparative analyzing of various kinds of technological reconstruction schemes, the operational mode of two 75t/h circulating fluidized Bed (CFB) boiler pressurized-fan is optimal transformed. From running constant-speed, the 90kW pressurized-fan is transformed into interlocking standby-heat and automatic start if necessary. The auxiliary power consumptions have been reduced greatly, and the good economic effects have been obtained.
出处 《节能技术》 CAS 2004年第5期44-45,共2页 Energy Conservation Technology
关键词 循环流化床锅炉 增压风机 运行方式 技术改造 CFB boiler Pressurized-fan Operational mode Optimal transform
  • 相关文献

参考文献3

  • 1车长源编著..锅炉风机节能技术[M].北京:中国电力出版社,1999:286.
  • 2刘德昌,陈汉平主编..锅炉改造技术[M].北京:中国电力出版社,2001:174.
  • 3刘家钰主编..电站风机改造与可靠性分析[M].北京:中国电力出版社,2002:298.