期刊文献+

2100t/h锅炉水冷壁管爆漏原因分析 被引量:3

CAUSE ANALYSIS OF WATER-WALL TUBE BURST AND LEAKAGE FOR A 2100t/h BOILER
下载PDF
导出
摘要 针对某火电厂 2 10 0t/h锅炉水封槽部位水冷壁管爆漏问题 ,通过宏观检验 ,化学成分、力学性能及金相组织分析等手段对其原因进行了分析 ,认为该爆管属于应力拉裂所致。对此 ,提出了相应的预防措施和建议。 Directing against the problems of water-wall tube burst and leakage in seal-water tank for a 2100 t/h boiler in one thermal power plant, the cause analysis has been carried out through several means, such as macroscopic examination, chemical composition analysis, mechanical performance analysis, and metallurgical structure analysis etc.. It is considered that the tube burst belongs in stress pull-breakage, and corresponding preventive measures and recommendations having been put forward for the said failures.
作者 何望飞 叶刚
出处 《热力发电》 CAS 北大核心 2004年第8期71-72,共2页 Thermal Power Generation
关键词 2100T/H锅炉 水冷壁管 爆漏 力学性能 金相组织分析 正压直吹式制粉系统 火电厂 boiler water wall failure stress concentration expansion burst and leakage