期刊文献+

9E发电机出口软连接断裂原因分析 被引量:1

CAUSE ANALYSIS OF OUTLET FLEXIBLE CONNECTOR’S BREAKAGE FOR 9E TYPE GENERATOR
下载PDF
导出
摘要 法国ALSTOM公司生产的 9E空冷发电机出口软连接铜片连续两次断裂 ,通过对材料不同区域、制造工艺、运行系统等方面进行试验和分析 ,认为软连接铜片断裂的主要原因是结构设计、制造工艺以及机械系统存在共振等所致 ,此结果对工程实际具有参考价值。 The outlet flexible connector’s copper leaves of 9E type air-cooled generator manufactured by ALSTOM Company in France have consecutively broken for two times. Through test and analysis from aspects of materials in different areas, fabricating technology, and operational systems etc., it is put forward that the main causes leading to breakage of flexible connector’s copper leaves are structure design, fabricating technology, and resonance existing in mechanical systems etc.. The results obtained have reference and guidance value for engineering practice.
机构地区 月亮湾燃机电厂
出处 《热力发电》 CAS 北大核心 2004年第8期68-70,共3页 Thermal Power Generation
关键词 9E空冷发电机 软连接铜片 断裂 机械系统 法国ALSTOM公司 generator flexible connector breakage metallurgical analysis resonance
  • 相关文献

参考文献4

  • 1GE公司.OPERATION AND MAINTENANCE MANUAL VOLUME 21[Z].,2001.. 被引量:2
  • 2高岩.1号发电机定子A0相软连接断裂检验报告[R].华南理工大学机械工程学院,2003.. 被引量:1
  • 3王荻 王飞.月亮湾电厂1号发电机中性点振动特性试验报告[R].广东省电力试验研究所,2002.. 被引量:2
  • 4华北电业管理局.电力工程电工手册(第一分册)[M].水利电力出版社,1985.. 被引量:1

共引文献1

同被引文献1

引证文献1

二级引证文献1