摘要
针对鹤岗电厂在试运行期间飞灰含碳量和排烟温度均高出设计值的问题,分析了其影响因素,给出了调整的方法。调整后两项运行参数达到了设计标准,降低了损失,提高了锅炉效率。
Both the carbon content in fly ash and the flue gas temperature of 300 MW boiler were higher than the designed values during the trial operation of Hegang Power Plant .The influencing factors were analyzed and the adjustment method was given. Through adjustment, these two operation parameters have reached the design standard,with the loss reduced and the boiler efficiency raised.
出处
《电力设备》
2004年第7期34-36,共3页
Electrical Equipment
关键词
锅炉
飞灰含碳量
排烟热损失
经济燃烧调整
bioler
carbon content in fly ash
rule gas heat loss
economic combustion adjustment