单纯采用十八胺对热力设备进行停运保护时 ,应防止其对凝结水处理系统树脂的污染。为此 ,研究了十八胺对离子交换树脂的污染规律 ,并提出了防范措施。该措施经二十余个装有 30 0MW及以上带凝结水处理机组的电厂的几十次实践 ,证明是有效的。
When octadecylamine is merely used for shutdown conservation of thermal power equipments, pollution of resin in condensate treatment system should be prevented. For this reason, the regularity of ion exchange resin polluted by octadecylamine has been studied, and preventive measure being recommended. The said measure has been implemented in more than twenty power plants with 300MW units for condensate treatment, it is shown from several tens practices that the said measure to be effective.
出处
《热力发电》
CAS
北大核心
2004年第7期64-67,共4页
Thermal Power Generation
基金
"上海市教委重点培育学科"项目资助
关键词
热力设备
停运保护
十八胺
凝结水处理
离子交换树脂
污染
thermal power equipment
shutdown conservation
octadecylamine
condensate treatment
ion exchange resin
pollution