摘要 目的 探讨微柱凝集技术在新生儿溶血病 (HDN)中的应用。方法 采用BioVue系统微柱凝集技术对 5 2例HDN患儿进行检测 ,同时用传统的试管法抗球蛋白试验作比较。结果 统计学上两种方法对HDN检出率无显著性差别 ,但微柱凝集技术能检出试管法所不能检出的阴性血样 ,比试管法检测凝集强度高 1+~ 2 +。结论 BioVue系统微柱凝集技术能快速准确检测出HDN ,具有更高的灵敏度 ,是直观可靠的方法。 Objective To discuss the application of CAT in testing HDN.Methods 52 newborns with HDN were tested by BioVue System CAT comparing with traditional TAT(Tube Agglutination Technique)anti human IgG test.Results In statistic, testing rate of the two methods in HDN was not obviously different,but CAT could test the negative blood samples that could not be tested by TAT and was higher 1+~2+ than TAT in agglutinate intention.Conclusion BioVue System CAT can test HDN quickly and exactly, its sensitivity was higher, the technique was reliable and directly observed.
出处 《中国实验诊断学》 2004年第3期297-298,共2页 Chinese Journal of Laboratory Diagnosis
关键词 微柱凝集技术 新生儿溶血病 CAT(Column Agglutination Technique) HDN(Hemolytic Disease of Newborn)
  • 相关文献

参考文献3

二级参考文献21

  • 1李代渝,赵华.博唯优单抗法测定Coombs试验的临床应用[J].临床输血与检验,2000,2(4):37-37. 被引量:1
  • 2刘莹 童军 见:李勇 杨贵贞主编.方法6微柱凝胶试验[A].见:李勇,杨贵贞主编.人类红细胞血型学使用理论与实验技术[C].北京:中国科学技术出版社,1999.276~278. 被引量:1
  • 3Lang B, Tissol C, Heyd C, et al. Red cell antibody screening, red cell antibody identification and compatibiliby testing with the CAT of Biovue system. Transfusion Clin Biol, 1994,1(2) : 121. 被引量:1
  • 4Ambuen L and South S. A sensitive specific and fast mathod for unexpected antibody detection using column agglutination technology.Transfusion, 1992,32 (Suppl) : 16. 被引量:1
  • 5Reisner RK, Ganthier CM, Williamson KR, et al. Compalison of patient ABO/rh/k typing by a column agglutination system and conventional tube method. Transfusion, 1993,33 (Suppl) : 18. 被引量:1
  • 6Rozman P, et al. Diagnostic value of gel cross-matching compared to the liss tube method. Vox Sang, 1996,70 : 103. 被引量:1
  • 7Bromilow IM. The use of the monodonal antibodies for blood typing and antibody screening by the gel test. Vox Sang, 1996,70:49. 被引量:1
  • 8Vengelen-Tyler V. In:American Association of Blood Banks. AABB technical. 12th od. Bethesda. New York: Karger 1996,606. 被引量:1
  • 9Kinght RC, et al. New technologies for red-cell serology. Blood Rev,1996,10 : 101. 被引量:1
  • 10Reis KJ, Chechowski R, Cupido A, et al. Column anti-human globulin test. Transfusion, 1993,33 ( 8 ) : 639. 被引量:1

共引文献60

同被引文献38

引证文献6

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部