期刊文献+

考虑水体晃动的水塔结构抗震性能分析 被引量:2

SEISMIC PERFORMANCE ANALYSIS OF WATER TOWER STRUCTURE CONSIDERING WATER SLOSHING
原文传递
导出
摘要 传统的水塔结构设计都忽略了水箱中水的晃动作用,把水当成质量块进行处理。将水箱中的水体当成一个TLD(调谐液体阻尼器),考虑水的晃动作用,根据有限元模拟分析,并结合实例对水塔结构进行抗震分析,得出水箱中的水有效地减小了水塔结构的地震反应,结构设计时应予以一定的考虑。 In the traditional water tower structure design,the slosh of water in the tank was ignored and the water was regarded as a mass block.In this paper,the water of the tank is took as a TLD(Tuned liquid damper) to consider the effect of the water sloshing.And then the seismic behavior of water tower was analyzed based on the finite element simulation analysis.The results show that the sloshing water of the tank reduces seismic response of water tower structures effectively.This useful effect should be considered when doing a structural design.
作者 李立 王泽军
出处 《工业建筑》 CSCD 北大核心 2013年第S1期214-217,共4页 Industrial Construction
关键词 水塔 TLD 时程分析 抗震分析 water tower TLD time-history analysis seismic analysis
  • 相关文献

参考文献4

  • 1尚春雨..带自由面水体的结构地震反应分析方法及应用[D].上海交通大学,2008:
  • 2周福霖著..工程结构减震控制[M].北京:地震出版社,1997:280.
  • 3Housner GW.Dynamic pressure on accelerated fluid container[].Bulletin of the Seismological Society of America.1957 被引量:1
  • 4Housner G W.The dynamic behavior of water tanks[].Bulletin of the Seismological Society of America.1963 被引量:1

同被引文献5

引证文献2

二级引证文献1