期刊文献+

两种机器人辅助下微创心脏手术的体外循环管理 被引量:1

The CPB Management of Mini Invasive Surgical Heart Operations by Two Different Robotic Assisted Systems
下载PDF
导出
摘要 目的分析比较两种机器人系统(AESOP3000和Da vinci S)辅助下微创心脏手术中体外循环管理和特点。方法 41例患者接受体外循环下微创机器人辅助心脏手术,两组均行股动静脉插管,A组(AESOP3000)共17例采用双极股静脉插管,D组(Da vinci S)共24例采用单极股静脉插管(Edward24/28F),加用离心泵辅助引流或负压辅助引流或颈内静脉插管辅助引流,建立体外循环。结果两组术中均引流充分,转流平稳,血流动力学稳定,监测指标均在正常范围,无手术死亡和围手术期并发症。结论根据不同的机器人辅助系统和不同的手术方式,选择正确合适的灌注引流途径,术中充分引流和灌注以及长时间稳定的灌注管理调整是保证机器人辅助微创心脏手术顺利、成功的重要因素。 Objective To summarize and analyze the experience of CPB establishment and management underwent with AESOP3000 and DA VINCI S robotic assisted systems.Methods 41 cases had been done with AESOP3000 and DA VINCI S robotic assisted systems.They were divided into two groups: AESOP3000 group(group A,n =17);DA VINCI S group(group D,n =24).The CPB was established through the cannulation into femoral artery and vein.Double-hole femoral vein cannulation was used in group A.While,sigle-hole femoral vein cannulation was applied in group D combined with Inter-jugular vein cannulation,vacuum assisted venous drainage or centrifugal assisted system.Results It was well-balanced and stably in CPB.All monitor indexes were in the normal range.No death and no paraoperative complication occurred in two groups.Conclusion We should choose the appropriate perfusion and drainage method according to the different surgical approaches and robotic assisted systems.And the sufficiency outflow and the well long-time perfusion management were the keys to surgical operation success.
出处 《生物医学工程学进展》 CAS 2013年第2期75-77,共3页 Progress in Biomedical Engineering
基金 上海市重点学课建设项目(B116)
关键词 体外循环 AESOP机器人辅助系统 DA VINCI机器人辅助系统 心脏外科 cardiopulmonary bypass,AESOP 3000 robotic assisted system,DA VINCI robotic assisted system,cardiac surgery
  • 相关文献

参考文献6

二级参考文献63

  • 1赵强.机器人辅助腔镜下房间隔缺损封堵术[J].中华医学杂志,2005,85(37):2597-2597. 被引量:5
  • 2黎京芳,张邻杰,宁晓华,于平,吴乃石,张明宇.真空辅助静脉引流技术的实验研究[J].哈尔滨医科大学学报,2006,40(6):506-508. 被引量:1
  • 3蔡俊锋,赵强.机器人辅助心脏外科手术术前规划的研究[J].上海医学,2006,29(12):894-896. 被引量:2
  • 4Loulmet D, Carpentier A, Attellis N, et al. Edoscopic coronary artery bypass grafting with the aid of robotic assisted instruments [J]. J Tborac Cardiovasc Surg, 2004, 118: 4-9. 被引量:1
  • 5Shin H, Yozu R, Maehara T, et al. Minimally invasive Port - Access coronary artery bypass grafting[ J ]. Ann Thorac Cardiovasc Surg, 2004, 5:191 -193. 被引量:1
  • 6Lucia T, Gennaro I, Ottavio A, et al. Totally endoscopic computer- enhanced atrial septal defect closure in six patients [J]. Ann Thorac Stag, 2006, 72:1354 -1357. 被引量:1
  • 7Hermann R, Dieter FIB, Helmut G, et al. Three -dimensional video and robot- assisted port- access mitral valve operation [J]. Ann Tnorac Surg, 2005, 69:1176-1182. 被引量:1
  • 8Galloway AC, Shemin RJ, Glower DD, et al. First report of the Port-Acoess international registry[J]. Ann Thomc Surg, 2004, 67:51 -56. 被引量:1
  • 9Jegger D, Tevaearai HT, Mueller XM, et al. Limitations Using the Vacuum - Assist Venous Drainage Technique During Cardiopulmonary Bypass Procedures [ J]. J Extra Corpor Technol, 2003, 35(3) : 207 -211. 被引量:1
  • 10Pappalardo F, Corno C, Franco A, et al. Reduction of hemodilution in small adult undergoing open heart surgery: a prospective, randomized trial [J]. Perfusion, 2007, 22(5): 317- 322. 被引量:1

共引文献23

同被引文献14

  • 1Navia JL, Cosgrove DM 3rd. Minimally invasive mitral valve opera- tions[ J]. Ann Thorac Surg, 1996,62(5) : 1542-1544. 被引量:1
  • 2Cohn LH, Adams DH, Couper GS, et al. Minimally invasive cardiac valve surgery improves patient satisfaction while reducing costs of car- diac valve replacement and repair [ J ]. Ann Surg, 1997, 226 ( 4 ) : 427-428. 被引量:1
  • 3Gammie JS, Zhao Y, Peterson ED, et al. J. Maxwell Chamberlain Memorial Paper for adult cardiac surgery. Less-invasive mitral valve operations : trends and outcomes from the Society of Thoracic Surgeons Adult Cardiac Surgery Database [J]. Ann Thorac Surg, 2010,90 (5) :1401-1408,1410. 被引量:1
  • 4McClure RS, Athanasopoulos LV, McGurk S, et al. One thousand minimally invasive mitral valve operations: early outcomes, late out- comes, and echoeardiographic follow-up [J]. J Thorac Cardiovasc Surg, 2013,145 (5) : 1199-1206. 被引量:1
  • 5Galloway AC, Schwartz CF, Ribakove GH, et al. A decade of mini- mally invasive mitral repair: long-term outcomes [ J]. Ann Thorac Surg, 2009,88 (4) : 1180-1184. 被引量:1
  • 6Iribarne A, Russo M J, Easterwood R, et al. Minimally invasive ver- sus stemotomy approach for mitral valve surgery : a propensity analysis [J]. Ann Thorac Surg, 2010,90(5) :1471-1478. 被引量:1
  • 7Seeburger J, Borger MA, Falk V, et al. Minimally invasive mitral valve surgery after previous sternotomy: experience in 181 patients [J]. Ann Thorac Surg ,2009, 87 (3):709-714. 被引量:1
  • 8Mandal K, Alwair H, Nifong WL, et al. Robotically assisted mini- really invasive mitral valve surgery [ J ]. J Thorac Dis, 2013,5 Suppl 6 : S694-703. 被引量:1
  • 9Mariscalco G, Musumeci F. The minithoracotomy approach: a safe and effective alternative for heart valve surgery [ J ]. Ann Thorac Surg, 2014,97 ( 1 ) :356-364. 被引量:1
  • 10段大为,李彤,张文芳,赵成秀,吴鹏,张强,胡晓旻.全胸腔镜心脏手术体外循环插管的选择[J].生物医学工程与临床,2010,14(3):225-228. 被引量:20