摘要
分析了减压塔底泵的抽空原因,提出了对引起减压塔底泵抽空因素的改进措施。这些措施可供同类装置的减压塔底泵工艺设计和技术改造时参考。
The reasons about residuum pump of decompression tower which does not suck areanalysed. Some improving measures are suggested for eliminating the reasons. The im-proving measures provide reference for technological design and technical innovation ofthe similar unit.
出处
《大庆石油学院学报》
CAS
北大核心
1993年第2期50-53,共4页
Journal of Daqing Petroleum Institute
关键词
减压塔
底泵
抽空
residuum pump of decompression tower
not sucking
reason analysis
improving measure