本文针对水泥磨机应用低压无功就地补偿技术措施,通过国有中型企业典型的一、二级供电网络补偿前后技术数据的变化,进行了理论计算分析,证明了该措施是一项投资少见效快的节能技术,还提出了该措施应用的场合及补偿效果较好的补偿体系。
The theoretical calculation and analysis on local compensation of low -voltage reactive power used in the cement mill and variation of technical data before and after compensation in typical first - class and second - class power supply networks of stateowned medium - sized enterprises shows that this is an energy saving technology with less investment and quick return. The appropriate fields for using this kind of compensation technology and compensation system with better effect are also proposed.