期刊文献+

屋面雨水回收用于冷却补水设计实例

Design Experience of Roof Rainwater Recycled as Makeup Water for Cooling Tower
下载PDF
导出
摘要 以广州某商业中心为例,介绍了屋面雨水回收用于空调冷却塔补水的设计。根据广州地区雨水资源丰富、水质良好及工程项目的特点,确定了雨水回收范围、回收用途,并进行了月均水量平衡计算。经济效益分析表明,该系统每年可节约市政供水34000m3,经济效益和环境效益显著。 A project design of roof rain water in a commercial centre for cooling tower's making up water was introduced. According to the abundant and good quality rain water resource in Guangzhou and the specialty of the project,the recycling scope and purpose of rain water were determined. The balance of monthly average rain water was calculated. Economic benefit analyzing showed that the system can save tap water 34 000m3 every year,its benefit of economy and environment is very distinguished.
作者 谢峰
机构地区 广州承总设计院
出处 《城市环境与城市生态》 CAS CSCD 2008年第6期40-42,共3页 Urban Environment & Urban Ecology
关键词 雨水利用 屋面雨水 冷却水 水量平衡 广州 rainwater utilization roof rainwater cooling water water balance Guangzhou