期刊文献+

双源CT在心源性疾病中的临床应用 被引量:2

Application of Dual Source Computed Tomography in Heart Diseases
下载PDF
导出
摘要 双源CT具有双球管和双组探测器,其单扇区重建时间分辨率可达到83ms,可在不控制心率的情况下获得高质量的冠状动脉血管图像及心脏成像,现就其在心源性疾病中的临床应用作一综述. The dual source computed tomographyis equipped with twoX- raytubes and twocorresponding detectors.with its 83 ms-temporal resolution of single segment reconstruction,high quality coronary artery CT angiography and heart can be acquired without heart rate control
出处 《昆明医科大学学报》 CAS 2009年第S1期129-132,共4页 Journal of Kunming Medical University
关键词 双源CT 冠状动脉 CT血管成像 Dual- source CT Coronaryartery CTangiography
  • 相关文献

参考文献13

  • 1张宗军,卢光明.双源CT及其临床应用[J].医学研究生学报,2007,20(4):416-418. 被引量:106
  • 2高莉,王继琛,邱建星,孙晓伟,高福生,唐光健,蒋学祥.多层螺旋CT血管成像评价冠状动脉血管旁路移植术[J].中国医学影像技术,2006,22(10):1496-1499. 被引量:2
  • 3Paul Stolzmann,Hans Scheffel,Thomas Schertler,Thomas Frauenfelder,Sebastian Leschka,Lars Husmann,Thomas G. Flohr,Borut Marincek,Philipp A. Kaufmann,Hatem Alkadhi.Radiation dose estimates in dual-source computed tomography coronary angiography[J]. European Radiology . 2008 (3) 被引量:1
  • 4Hans Scheffel,Hatem Alkadhi,André Plass,Robert Vachenauer,Lotus Desbiolles,Oliver Gaemperli,Tiziano Schepis,Thomas Frauenfelder,Thomas Schertler,Lars Husmann,Jürg Grunenfelder,Michele Genoni,Philipp A. Kaufmann,Borut Marincek,Sebastian Leschka.Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J]. European Radiology . 2006 (12) 被引量:1
  • 5Thomas G. Flohr,Cynthia H. McCollough,Herbert Bruder,Martin Petersilka,Klaus Gruber,Christoph Sü?,Michael Grasruck,Karl Stierstorfer,Bernhard Krauss,Rainer Raupach,Andrew N. Primak,Axel Küttner,Stefan Achenbach,Christoph Becker,Andreas Kopp,Bernd M. Ohnesorge.First performance evaluation of a dual-source CT (DSCT) system[J]. European Radiology . 2006 (6) 被引量:1
  • 6Francesca Pugliese,Nico R. A. Mollet,Giuseppe Runza,Carlos Mieghem,Willem B. Meijboom,Patrizia Malagutti,Timo Baks,Gabriel P. Krestin,Pim J. deFeyter,Filippo Cademartiri.Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris[J]. European Radiology . 2006 (3) 被引量:1
  • 7Flohr,T.G.,McCollough,C.H.,Bruder,H.First performance evaluation of a dual-source CT (DSCT) system. European Radiology . 2006 被引量:1
  • 8Flohr,TG,Stierstorfer,K,Ulzheimer,S.Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot. Medical Physics . 2005 被引量:1
  • 9P Stolzmann,H Scheffel,T Schertler.Radiation dose estimates in dual-source computed tomography coronary angiography. European Radiology . 2008 被引量:1
  • 10Stein,PD,Beemath,A,Kayali,F.Multidetector computed tomography for the diagnosis of coronary artery disease: a systematic review. The American Journal of Medicine . 2006 被引量:1

二级参考文献19

共引文献106

同被引文献28

  • 1庄磊,甘继宏,刘建军,王伟娟,袁芳,王忠明,藏建华.双源CT血管造影评价冠状动脉狭窄的临床价值[J].西北国防医学杂志,2010,31(4):273-275. 被引量:9
  • 2虞崚崴,汤光宇.双源CT冠状动脉血管成像的临床应用[J].中国医学影像技术,2009,25(S1):206-209. 被引量:6
  • 3郭华,张龙江,江时森,王立军,钟勇,汤沂,卢光明.双源CT成像在评价冠状动脉狭窄中价值的初步探讨[J].医学研究生学报,2007,20(7):727-730. 被引量:46
  • 4Matt D,Scheffel H,Leschka S,et al.Daul-source CT corunay amgiigraphy:image quality,mean heart rate,and heart raie variadility[J],Am J Rientgenol,2007,189(3):567-573. 被引量:1
  • 5Scheffe IH,Alkadh IH,Plass A,et al.Accuracy of dual-source CTcoronary angiography.first experience in a high pre-test probed ility population w ithout heart rate control[J].Eur Radiol,2006,16(12):2739-2747. 被引量:1
  • 6Mohlenkamp S,Hort W,Ce JB,et al.Update on myocardial bridging[J].Circulation,2002,106(20):2616-2622. 被引量:1
  • 7Lu GM,Zhang LJ,Guo H,et al.Comparison of myocardial bridging by dual-source CT with conventional coronay angiography[J].Cire,2008,72(7):1079-1085. 被引量:1
  • 8Pugliese F,Mollet NR,Runza G,et al.Diagnostic accuracy of non-invasive 64-slice CTcoronary angiography in patients with stable angina pectoris[J].Eur Radiol,2006,16:575-582. 被引量:1
  • 9Stein PD,Beemath A,Kayal IF,et al.Multidetecor computed tomtography in the diagnosis of coronary artery disease:a systematic rcview[J].Am J Med,2006,119(3):203-216. 被引量:1
  • 10Hans S,Hatem A,Anere P,et al.A couracy of dual-source CT coronary angiography,First experience in a pre-test probab ility population w ithout heart rate control[J].Eur Radiol,2006,16(12):2739-2747. 被引量:1

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部