摘要 目的评价金沉积、金合金和镍铬合金3种不同基底烤瓷冠临床应用效果。方法对2004年5月至2006年5月在辽宁省妇幼保健院口腔科进行烤瓷冠修复的患者35例(120颗牙),根据患者要求分别制作镍铬合金基底、金合金基底、金沉积基底烤瓷冠,每种基底烤瓷冠40颗牙。观察比较戴冠2年后3组烤瓷冠在颜色、边缘的密合度、牙龈染色等方面的情况。结果金合金基底、金沉积基底烤瓷冠在颜色、冠边缘的密合度及颈缘染色均优于镍铬合金基底烤瓷冠,差异有统计学意义(P<0.05)。结论金合金基底和金沉积基底烤瓷冠临床效果好。 Objective To compare the clinical effect of the ceramic crowns made of Ni-Cr alloy,gold alloy,gold-electroforming.Methods One hundred and twenty ceramic crowns were made of three alloys respectively(40 pieces eacht ype).The color,margin fitness and cervical gray line of the ceramic crowns were checked after 2 years.Results Theg old-electroforming and gold alloy ceramic crowns were better than the Ni-Cr alloy ceramic crowns in color,cervicalg ray line and margin fitness(P<0.05).Conclusion The clinical effect of gold alloy and gold-electroforming ceramicc rowns is better than the Ni-Cr alloy ceramic crowns.
作者 金长山
出处 《中国实用口腔科杂志》 CAS 2009年第3期174-175,共2页 Chinese Journal of Practical Stomatology
关键词 烤瓷冠 金沉积 金合金 镍铬合金 ceramic crowns electroforming gold alloy Ni-Cr alloy
  • 相关文献

参考文献10

二级参考文献17

  • 1林肇琦.有色金属材料学(第一版)[M].沈阳:东北工学院出版社,1995.2-10,28-33. 被引量:1
  • 2[1]Blanco-Dalmau L. The nickel problem. J Prosthet Dent 1982;48:99-101. 被引量:1
  • 3[2]Asgar K, Morris, H, Dootz Ochi S, Loreg R. Properities and composition of many newing developed crown and bridge alloys. J Dent Res 1981;61:284. 被引量:1
  • 4[1]Donovan T,Prince J.An analysis of margin configurations for metal-ceramic crowns.J Prosthet Dent,1985,53(2):153-7. 被引量:1
  • 5[2]Magne P,Magne M,Belser U.The esthetic width in fixed prosthodontics.J Prosthet Dent,1999,8(2):106-1. 被引量:1
  • 6[3]Goodacre CJ,Dykema EW,Ullmann RB.The collarless metal-ceramic crown.J Prosthet Dent,1977,38(6):615-22. 被引量:1
  • 7[4]Sorensen JA,Okamoto SK,Seghi RR,et al.Marginal fidelity of four methods of swaged metal matrix crown fabrication.J Prosthet Dent,1992,67(2):162-73. 被引量:1
  • 8[5]Fradeani M.Clinical experience with empress crowns.Int J Prothodont,1997,10:241-247. 被引量:1
  • 9[6]Haselton DR,Diaz-Arnold AM,Hillis SL.Clinical assessment of high-strength all-ceramic crowns.J Prosthet Dent,2000,83:396-401. 被引量:1
  • 10[7]Molin MK,Karlsson SL.A randomized 5-year clinical evaluation of 3 ceramic inlay systems.Int J Prothodont,2000,13:194-200. 被引量:1

共引文献176

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部