摘要
A micro-plate magnetic chemiluminescence immunoassay was developed for rapid and high throughput detection of carcinoembryonic antigens (CEA) in human sera. This method was based on a sandwich immunoreaction of fluorescein isothiocyanate (FITC)-labeled anti-CEA antibodies, CEA antigens, and horseradish peroxidase (HRP)-conjugated anti-CEA antibodies in mi- cro-plate. The immunomagnetic particles coated with anti-FITC antibodies were used as the solid phase for the immunoassay. The separation procedure was carried out by a magnetic plate adaptor and the luminol-hydrogen peroxide (H2O2)-HRP system was employed for the chemiluminescence detection. The proposed method combined the advantages of the micro-plate reactor and magnetic particle separation technology with the linear range of 5-250 ng mL·1. The detection limit of CEA was 0.61 ng mL·1. The coefficient of the variation was less than 7% and 13% for intra-assay and inter-assay precision, respectively. Compared with the commercial micro-plate chemiluminescent kit, the proposed method showed a good correlation.
A micro-plate magnetic chemiluminescence immunoassay was developed for rapid and high throughput detection of carcinoembryonic antigens (CEA) in human sera. This method was based on a sandwich immunoreaction of fluorescein isothiocyanate (FITC)-labeled anti-CEA antibodies, CEA antigens, and horseradish peroxidase (HRP)-conjugated anti-CEA antibodies in mi- cro-plate. The immunomagnetic particles coated with anti-FITC antibodies were used as the solid phase for the immunoassay. The separation procedure was carried out by a magnetic plate adaptor and the luminol-hydrogen peroxide (H2O2)-HRP system was employed for the chemiluminescence detection. The proposed method combined the advantages of the micro-plate reactor and magnetic particle separation technology with the linear range of 5-250 ng mL·1. The detection limit of CEA was 0.61 ng mL·1. The coefficient of the variation was less than 7% and 13% for intra-assay and inter-assay precision, respectively. Compared with the commercial micro-plate chemiluminescent kit, the proposed method showed a good correlation.
作者
LI ZhiYong1, ZHANG QianYun2, ZHAO LiXia1, LI ZhenJia3, HU GuoMao3, LIN Jin-Ming2 & WANG Shan4 1State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
2Department of Chemistry, Tsinghua University, Beijing 100084, China
3Beijing Chemclin Biotech Co., Ltd., Beijing Academy of Science and Technology, Beijing 100094, China
4School of Chemistry and Chemical Engineering, Xianyang Normal College, Xianyang 712000, China
基金
support from the CAS Major Scientific Research and Equipment Development Projects (YZ-0632)
the National Natural Science Founolation of China (Grant No. 20907060)
the CAS Graduate Innovation Foundation (No. YXLW-3)
the National key Technology R&D Program (Grant No. 2006BAF07B03-1-1)
Shaanxi Province, China’s Scholarship Council (Grant No. 08JK482)