Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses 被引量:4

Finite Element Analysis of the Contact Mechanics of Ceramic-on-Ceramic Hip Resurfacing Prostheses
下载PDF
导出
摘要 Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces. Ceramics are good alternative to metal as bearing couple materials because of their better wear resistance. A Finite Element(FE) study was performed to investigate the contact mechanics and stress distribution of Ceramic-on-Ceramic (COC) hip resurfacingprostheses. It was focused in particular on a parametric study to examine the effects of radial clearance, loading,alumina coating on the implants, bone quality, and fixation of cup-bone interface. It was found that a reduction in the radialclearance had the most significant effect on the predicted contact pressure distribution among all of the parameters considered inthis study. It was determined that there was a significant influence of non-metallic materials, such as the bone underneath thebearing components, on the predicted contact mechanics. Stress shielding within the bone tissue was found to be a major concernwhen regarding the use of ceramic as an alternative to metallic resurfacing prostheses. Therefore, using alumina implantswith a metal backing was found to be the best design for ceramic resurfacing prostheses in this study. The loading, bone quality,and acetabular cup fixation conditions were found to have only minor effects on the predicted contact pressure distribution alongthe bearing surfaces.
出处 《Journal of Bionic Engineering》 SCIE EI CSCD 2010年第3期244-253,共10页 仿生工程学报(英文版)
关键词 contact mechanics HIP RESURFACING CERAMIC finite element analysis contact mechanics hip resurfacing ceramic finite element analysis
  • 相关文献

参考文献50

  • 1Harlan C. Amstutz,Peter Grigoris,Frederick J. Dorey.Evolution and future of surface replacement of the hip[J]. Journal of Orthopaedic Science . 1998 (3) 被引量:1
  • 2F. Higuchi,A. Inoue,M. Semlitsch.Metal-on-metal CoCrMo McKee-Farrar total hip arthroplasty: characteristics from a long-term follow-up study[J]. Archives of Orthopaedic and Trauma Surgery . 1997 (3) 被引量:1
  • 3Mai M T,,Schmalzried T P,Dorey F J,Campbell P A,Amstutz H C.The contribution of frictional torque to loosening at the cement-bone interface in Tharies hip replacements. Journal of Bone and Joint Surgery British Volume . 1996 被引量:1
  • 4MacDonald S J,McCalden R W,Chess D G,Bourne R B,Rorabeck C H,Cleland D,Leung E.Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial. Clinical Orthopaedics . 2003 被引量:1
  • 5Isaac G H,,Thompson J,Williams S,Fisher J.Metal-on-metal bearings surfaces: Materials, manufacture, design, optimization, and alternatives. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine . 2006 被引量:1
  • 6Learmonth I D,Gheduzzi S,Vail T P.Clinical experience with metal-on-metal total joint replacements: Indications and results. Proceedings of the Institution of Mechanical Engineering, Part H: Journal of Engineering in Medicine . 2006 被引量:1
  • 7McKellop H,Park S H,Chiesa R,Doorn P,Lu B,Normand P,Grigoris P,Amstutz H.In vivo wear of three types of metal on metal hip prostheses during two decades of use. Clinical Orthopaedics and Related Research . 1996 被引量:1
  • 8Mantell S C,Chanda H,Bechtold,J E,Kyle R F.A parametric study of acetabular cup design variables using finite element analysis and statistical design of experiments. Journal of Biomechanical Engineering-Transactions of the ASME . 1998 被引量:1
  • 9Stansfield B W,Nicol A C.Hip joint contact forces in normal subjects and subjects with total hip prostheses: walking and stair and ramp negotiation. Clinical Biomechanics . 2002 被引量:1
  • 10Suh M S,Chae Y H,Kim S S.Friction and wear behavior of structural ceramics sliding against zirconia. Wear . 2008 被引量:1