摘要 AIM:To investigate intra-operator variability of semiquantitative perfusion parameters using dynamic contrast-enhanced ultrasonography(DCE-US),following bolus injections of SonoVue.METHODS:The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank.In the in vivo experiments,B16F10 melanoma cells were xenografted to five nude mice.Both in vitro and in vivo,images were acquired following bolus injections of the ultrasound contrast agent SonoVue(Bracco,Milan,Italy) and using a Toshiba Aplio ultrasound scanner connected to a 2.9-5.8 MHz linear transducer(PZT,PLT 604AT probe)(Toshiba,Japan) allowing harmonic imaging("Vascular Recognition Imaging") involving linear raw data.A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute,Villejuif,France and used to evaluate seven perfusion parameters from time-intensity curves.Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation(CV).RESULTS:In vitro,different volumes of SonoVue were tested with the three phantoms:intra-operator variability was found to range from 2.33% to 23.72%.In vivo,experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%.In addition,the area under the curve(AUC) and the area under the wash-out(AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%.CONCLUSION:AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values. AIM: To investigate intra-operator variability of semi-quantitative perfusion parameters using dynamic contrast-enhanced ultrasonography (DCE-US), following bolus injections of SonoVue?.METHODS: The in vitro experiments were conducted using three in-house sets up based on pumping a fluid through a phantom placed in a water tank. In the in vivo experiments, B16F10 melanoma cells were xenografted to five nude mice. Both in vitro and in vivo, images were acquired following bolus injections of the ultrasound contrast agent SonoVue? (Bracco, Milan, Italy) and using a Toshiba Aplio? ultrasound scanner connected to a 2.9-5.8 MHz linear transducer (PZT, PLT 604AT probe) (Toshiba, Japan) allowing harmonic imaging (“Vascular Recognition Imaging”) involving linear raw data. A mathematical model based on the dye-dilution theory was developed by the Gustave Roussy Institute, Villejuif, France and used to evaluate seven perfusion parameters from time-intensity curves. Intra-operator variability analyses were based on determining perfusion parameter coefficients of variation (CV).RESULTS: In vitro, different volumes of SonoVue? were tested with the three phantoms: intra-operator variability was found to range from 2.33% to 23.72%. In vivo, experiments were performed on tumor tissues and perfusion parameters exhibited values ranging from 1.48% to 29.97%. In addition, the area under the curve (AUC) and the area under the wash-out (AUWO) were two of the parameters of great interest since throughout in vitro and in vivo experiments their variability was lower than 15.79%.CONCLUSION: AUC and AUWO appear to be the most reliable parameters for assessing tumor perfusion using DCE-US as they exhibited the lowest CV values.
机构地区 IR Department of Imaging
出处 《World Journal of Radiology》 CAS 2011年第3期70-81,共12页 世界放射学杂志(英文版)(电子版)
关键词 Dynamic CONTRAST-ENHANCED ultrasonography Intra-operator VARIABILITY Functional imaging SEMI-QUANTITATIVE PERFUSION parameters Linear raw data Quantification Dynamic contrast-enhanced ultrasonography Intra-operator variability Functional imaging Semi-quantitative perfusion parameters Linear raw data Quantification
  • 相关文献

参考文献55

  • 1J. R. Eisenbrey,F. Forsberg.Contrast-enhanced ultrasound for molecular imaging of angiogenesis[J]. European Journal of Nuclear Medicine and Molecular Imaging . 2010 (1) 被引量:1
  • 2Gregory M. Lanza,Shelton D. Caruthers,Patrick M. Winter,Michael S. Hughes,Anne H. Schmieder,Grace Hu,Samuel A. Wickline.Angiogenesis imaging with vascular-constrained particles: the why and how[J]. European Journal of Nuclear Medicine and Molecular Imaging . 2010 (1) 被引量:1
  • 3Nathalie Lassau,Mohamed Chebil,Linda Chami,Sophie Bidault,Elizabeth Girard,Alain Roche.Dynamic contrast-enhanced ultrasonography (DCE-US): a new tool for the early evaluation of antiangiogenic treatment[J]. Targeted Oncology . 2010 (1) 被引量:1
  • 4Sergio Casciaro,Francesco Conversano,Stefano Musio,Ernesto Casciaro,Christian Demitri,Alessandro Sannino.Full experimental modelling of a liver tissue mimicking phantom for medical ultrasound studies employing different hydrogels[J]. Journal of Materials Science: Materials in Medicine . 2009 (4) 被引量:1
  • 5Ashley M. Groves,Vicky Goh,Sabarinath Rajasekharan,Irfan Kayani,Raymondo Endozo,John C. Dickson,Leon J. Menezes,Manu Shastry,Said B. Habib,Peter J. Ell,Brian F. Hutton.CT coronary angiography: Quantitative assessment of myocardial perfusion using test bolus data–initial experience[J]. European Radiology . 2008 (10) 被引量:1
  • 6Sergio Casciaro,Christian Demitri,Francesco Conversano,Ernesto Casciaro,Alessandro Distante.Experimental investigation and theoretical modelling of the nonlinear acoustical behaviour of a liver tissue and comparison with a tissue mimicking hydrogel[J]. Journal of Materials Science: Materials in Medicine . 2008 (2) 被引量:1
  • 7Emilio Quaia.Microbubble ultrasound contrast agents: an update[J]. European Radiology . 2007 (8) 被引量:2
  • 8Martijn R. Meijerink,Hester Cruijsen,Klaas Hoekman,Matthijs Kater,Cors Schaik,Jan Hein T. M. Waesberghe,Giuseppe Giaccone,Radu A. Manoliu.The use of perfusion CT for the evaluation of therapy combining AZD2171 with gefitinib in cancer patients[J]. European Radiology . 2007 (7) 被引量:2
  • 9Emilio Quaia,Mirko D’Onofrio,Alessandro Palumbo,Stefania Rossi,Stefano Bruni,Maria Cova.Comparison of contrast-enhanced ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver: diagnostic performance and confidence[J]. European Radiology . 2006 (7) 被引量:2
  • 10Technology overview: sonoVue[J]. European Radiology Supplements . 2004 (8) 被引量:1