期刊文献+

改进流动注射光度法测定含悬浮颗粒水样中总氮含量

Measurement of total nitrogen in water with suspended particles by improved flow injection spectrophotometry
下载PDF
导出
摘要 用流动注射法测量含颗粒物水样中总氮,采用较粗管路和快速微波消解法,水样经预处理后,再使用自制在线过滤装置除去消解残渣。总氮的检出限为0.040mg/L,检测范围为0~10.0mg/L。本方法连续测定含悬浮颗粒水样,流路无堵塞,对湖水、生活污水和工业废水实际含悬浮颗粒水样中总氮的测定,加标回收率为99.6%~103.5%。 With the adoption of wide diameter tube system and quick microwave digesting method.using the on-line filter to dregs after pretreatment of water samples,the flow injection spectrophotometry was applied in determination of total nitrogen in water with suspended particles.All conditions were optimized.The detection limit of 0.040mg/L and the linearity ranges of 0~10.0 mg/L total nitrogen were achieved.The proposed method was continually applied to measure the water samples with suspended particles of lake water,domestic waste water and industrial waste water,and get the recoveries of 99.6% to 103.5% by the standard addition method.
出处 《水资源与水工程学报》 2012年第3期105-107,共3页 Journal of Water Resources and Water Engineering
关键词 流动注射 微波消解 在线过滤 悬浮颗粒 总氮 flow injection microwaves digesting on-line filtrating suspended particles total nitrogen
  • 相关文献

参考文献5

  • 1Mason C J,Coe G,Edwards M,et al.The use of microwaves in the acceleration of digestion and colour development in the determination of total Kjeldahl nitrogen in soil[].The Analyst.1999 被引量:1
  • 2Benson R L,Truong Y B,Mckelvie I D,et al.Monitoring of dissolved reactive phosphorus in waste waters by flow in-jection analysis,Part1,Method development and valida-tion[].Water Research.1996 被引量:1
  • 3方肇伦,徐淑坤.流动注射分析[J].分析试验室,1993,12(2):97-110. 被引量:7
  • 4陈林枫.流动注射分析仪在测定水体总氮中的实验研究[J].干旱环境监测,2010,24(4):193-197. 被引量:2
  • 5方肇伦等著..流动注射分析法[M].北京:科学出版社,1999:410.

二级参考文献68

共引文献7