摘要
结合可门电厂工程实际,采用数值模拟和物理模型试验相结合的方法,对电厂附近潮汐水域的水力热力特性进行了系统的研究。数值模拟和物理模型试验是分析温排水在受纳水域中扩散运移规律的有效方法,可以模拟电厂冷却水排放所产生的流速场、温度场,分析热量的影响范围、时间及强度,优化取排水口工程布置。
Combined with the situation of Kemen power station,the hydraulic and thermal characteristic in full tide near the power station have been studied by numerical simulation and physical model systemically.Numerical simulation and physical model are effective methods to analyze the diffuse and transfer rule of warm water in acceptance water,which can simulate the velocity and temperature field,analyze the heat affected area,time and intensity,optimize the intake and discharge disposal.
出处
《水资源与水工程学报》
2012年第1期153-156,共4页
Journal of Water Resources and Water Engineering
关键词
冷却水
水力特性
热力特性
物理模型
数学模拟
cooling water
hydraulic characteristic
thermal characteristic
physical model
numerical simulation