摘要
介绍了反渗透装置进水的预处理系统和反渗透装置的运行状况。包括预处理工艺的选择、活性炭的影响、混凝剂的应用等;探讨了进水温度、压力和pH值对反渗透装置的影响。
The water pretreatment system and operation of reverse osmosis unit were introduced,including pretreatment process selection,impact of active carbon and application of coagulant,etc.The impact of water inlet temperature,pressure and pH value on reverse osmosis unit operation is discussed.
出处
《炼油技术与工程》
CAS
2010年第4期61-63,共3页
Petroleum Refinery Engineering
关键词
反渗透
除盐水
预处理
运行
reverse osmosis
desalted water
pretreatment
operation