对北仑发电厂二期600MW锅炉的燃煤特性、设备结构和运行条件进行分析 ,并通过配煤掺烧调整试验 ,确定了适用的煤种和燃烧器配风方式 ,解决了锅炉燃烧器区域严重结渣问题 。
Based on the analysis of the coal-fired characteristis,equipment struc ture, operation condition for 600 MW coal-fired boiler of Beilun thermal power p lant phase II, and adjustment test of coal mixture burning, the adaptive coal ty pe and manner of air distribution of burner were determined. It resolved the ser ious slagging problems around the burner area of boiler and realized the better match between the boiler type and coal characteristics.
出处
《浙江电力》
2003年第4期5-8,共4页
Zhejiang Electric Power
关键词
锅炉
煤种
适应性
研究
boiler
coal type
adapation
research