摘要
针对混凝除镉应急工程及其效果进行了回顾与总结;对水厂内各种投药除镉技术进行了试验对比与效果分析,建议采用加碱调高pH值的方式强化除镉。
Emergent treatment for removing cadmium by coagulation and its effect were summarized. Enhanced cadmium removal by increasing pH value using alkali is proposed after comparative experiments and effect analysis of various cadmium removal methods by adding coagulant in water works.
出处
《供水技术》
2007年第2期25-27,共3页
Water Technology
关键词
镉污染
应急处理
北江
混凝除镉
cadmium pollution
emergent treatment
Beijiang River
cadmium removal by coagulation