期刊文献+

用微型地下室坑式摆墩方式解决BBVS-60宽频带地震计零漂问题 被引量:5

Setting an instrument frustum in a semi-subterranean hole to reduce environmental affecting
下载PDF
导出
摘要 分析了在四川省西昌数字测震台网"十五"项目中安装BBVS-60和CMG-3ESPC三分向宽频带地震计记录时遇到的零漂问题。通过实例证明了在一体化的地表观测房中,通过修建微型地下室构筑坑式摆墩的方法,能够有效解决由于环境变化产生的宽频带地震计记录时遇到的零漂问题,确保宽频带地震计正常记录工作。优点有:(1)满足了宽频带地震计对观测环境条件的要求;(2)大幅度降低了工程造价;(3)便于地震计维护;(4)有效地降低了地表噪声水平。 In order to reduce the zero shifts of digital seismographs,which are BBVS-60 and CMG-3ESPC,due to environmental affecting,we dig a deep chuckhole,in which an instrument frustum is constructed,in an observation house.We put the broadband digital seismometers on the instrument frustum.We then made a comparative test and got a satisfy result.Our test result indicate that installing BBVS-60 and CMG-3ESPC wide frequency range seismometer on the instrument frustum can effectively reduce the ground noise,ensured t...
出处 《四川地震》 2009年第1期20-24,共5页 Earthquake Research in Sichuan
关键词 宽频带地震计 零漂 微型地下室 摆墩 开环周期 broadband seismograph zero shift semi-subterranean hole
  • 相关文献

参考文献4

二级参考文献16

  • 1中国地震局监测预报司编.数字地震观测技术[M].北京:地震出版社,2003.. 被引量:12
  • 2Wielandt E. 2002. International Handbook of Earthquake & Engineering Seismology[M]. Seismometry Part A:283-304 被引量:1
  • 3叶林才.反馈地震计(下)[J].地震地磁观测与研究,1984,5(2):40-52. 被引量:1
  • 4Aki K and Richards P G. 1980. Quantitative Seismology[J]. Freeman, San Francisco, Vol. Ⅰ 被引量:1
  • 5Bormann P. 2002. Seismic Signals and Noise[M]. Chapter 4 of "New Manual of Seismological Observatory Practice". Geo Forschungs Zentrum Potsdam 被引量:1
  • 6Holcomb G L and Hutt C R. 1992. An evaluation of installation methods for STS-1 seismometers[J]. Open-File Report 92-302, U S Geological Survey, Albuquerque, NM 被引量:1
  • 7Mc Namara D E and Buland R P. 2004. Ambient Noise Levels in the Continental United States[J]. Bull Seism Soe Am, 94 (4):1 517-1 527 被引量:1
  • 8Peterson J. 1993. Observations and modeling of seismic background noise[J]. U S Geological Survey Open-File Report, 93-322 被引量:1
  • 9UCB S L. 1997. Guidelines for installing broadband seismic instrumentation[DB], http://www. seismo. berkeley. edu/ seismo/bdsn/instrumentation/guidelines.html. 被引量:1
  • 10Wielandt E. 2002. Seismic Sensors and their Calibration[M]. Chapter 5 of "New Manual of Seismological Observatory Practice". Geo Forschungs Zentrum Potsdam 被引量:1