期刊文献+

三椎体与二椎体复位固定治疗腰椎滑脱症螺钉局部受力的生物力学评价 被引量:1

Biomechanical evaluation of the stress along the screws of different posterior internal fixation in the treatment of lumbar spondylolishesis
下载PDF
导出
摘要 目的比较脊柱滑脱中两种后路固定方法中螺钉局部受力情况。方法采用6具新鲜成人尸体脊柱标本(L1-L5),Panjabi法制备腰椎滑脱模型,固定器械为SINO椎弓根钉及固定棒。应用电阻应变测量法及生物力学测量方法,通过INSTRON5567材料实验机对标本进行垂直压缩、前屈、后伸、左右侧屈5种状态的测试。实验分为二椎体固定组(A组)和三椎体固定组(B组)。结果二椎体固定组在垂直压缩、前屈、左右侧弯运动时提拉钉所受应力大于三椎体固定组(P<0.05)。结论三椎体固定时提拉钉根部所受应力小于二椎体固定,能够有效降低螺钉因疲劳产生应力集中而发生断裂的概率。 Objective To measure and compare the stresses along the screws in three-segment and two-segment posterior internal fixation in spondylolishesis.Method Six fresh samples of human lumbar vertebras were used in the study.The spondylolishesis model was made by Panjabi method,and was placed with the universal spine system of SINO.By strain measurement and biomechanical measurement,the samples were tested in 5 different directions with INSTRON 5567.Stress along the screws for two-segment(group A) and three-segmen...
出处 《医用生物力学》 CAS CSCD 2008年第5期372-375,共4页 Journal of Medical Biomechanics
关键词 腰椎滑脱 生物力学 内固定器 电阻应变计 Spondylolishesis Biomechanics Internal fixation Strain gauge
  • 相关文献

参考文献2

二级参考文献2

共引文献76

同被引文献11

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部