期刊文献+

淋巴循环动力学模型研究 被引量:8

A Dynamic Model Describing Lymphatic Circulation
下载PDF
导出
摘要 根据淋巴管的形态、功能、以及淋巴微循环调控机制的研究成果,在充分考虑血液、组织液和淋巴液相互作用的动态系统基础上,仿照Sungawa心输出量的分析方法,建立了一个描述淋巴循环的动力学模型,并将模型的理论研究结果与Ikomi的按摩对兔后腿淋巴流量影响的实验相对照,发现两者符合程度较高,表明该模型对于分析淋巴形成的动力学机制有一定的意义,特别分析了淋巴流量与按摩频率的关系,可用于临床分析推拿等外治疗法对淋巴循环的影响。 Based on the morphology and function of lymphatic vessel, and on the achievements of researches in the regulatory mechanism of lymphatic circulation, we fully considered the dynamic interaction of blood, interstitial fluid and lymph fluid; then we imitated and used Sungawa s method of analyzing the heart output, and finally set up a dynamic model for describing lymphatic circulation. Comparison of our calculating results with the data from Ikomi s experiment showed that they were identical, thus indicating ...
出处 《生物医学工程学杂志》 CAS CSCD 北大核心 2008年第4期831-834,共4页 Journal of Biomedical Engineering
基金 973计划项目资助(2005CB523306) 上海市科技发展基金资助项目(05DZ19747) 上海市重点学科建设资助项目(T0302)
关键词 淋巴循环 压力容积环 当量弹性模量 按摩 推拿 Lymphatic circulation Pressure-Volume circle Equivalent elastance Massage
  • 相关文献

参考文献10

  • 1[1]Ikomi F,Schmid-Schonbein GW,Lymph pump mechanics in the rabbit hind leg.Am J Physiol,1996; 271:173 被引量:1
  • 2[2]Mendoza E,Schmid-Schonbein GW.A model for mechanics of primary lymphatic valves.J of Biomechanical engineering-Transactions of the ASME,2003; 125 (3):407 被引量:1
  • 3[4]Sunagawa K,Sagawa K,Maughan WL,et al.Ventricular interaction with the vascular system in terms of pressure-volume relationships,In:Yin FCPed.Ventricular /vascular coupling.New York:Spring-Verlag Press,1987:210 被引量:1
  • 4[5]Gashev AA,Davis MJ,Zawieja DC.Inhibition of the active lymph pump by flow in rat mesenteric lymphatic and thoracic duct.J Physiology,2002; 540 (3):1023 被引量:1
  • 5[6]Li B.,Silver I,Szalai JP,et al.Pressure-Volume relationships in sheep mesenteric lymphatic vessels in situ:response to hypovolemia.Microvascular Research,1998; 56:127 被引量:1
  • 6[7]Yuan Z,Boulanger B,Flessner M,et al.Relationship between pericardial pressure and lymphatic pericardial fluid transport in sheep.Microvascular Research,2000; 60:28 被引量:1
  • 7[8]Sabaratnam S,Mason RM,Levick JR.Inside-Out cannulation of fine lymphatic trunks used to quantify coupling between transsynovial flow and lymphatic drainage from rabbit knees.Microvascular Research,2002; 64:1 被引量:1
  • 8[9]Swartz MA,Kaipainen A,Netti PA,et al.Mechanics of interstitial-lymphatic fluid transport:theoretical foundation and experimental validation.J Biomechanics,1999; 32:1297 被引量:1
  • 9[10]Campisi C,Boccardo F,Zilli A,et al.Long-term results after lymphatic-venous anastomoses for the treatment of obstructive lymphedema.Microsurgery,2001; 21 (4):135 被引量:1
  • 10[11]Laine GA,Allen SJ,Gabel JC,et al.Outflow pressure reduces lymph flow rate from various tissues.Microvasc,1987; 33:135 被引量:1

同被引文献66

引证文献8

二级引证文献104

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部