期刊文献+

Finite element analysis of stress distribution of obturator prostheses for acquired unilateral maxillary defects 被引量:2

Finite element analysis of stress distribution of obturator prostheses for acquired unilateral maxillary defects
下载PDF
导出
摘要 Objective To assess stresses produced by different obturator prostheses. Methods Three-dimensional finite clement models of unilateral maxillary defects rehabilitated with different obturators were constructed. The different stresses were analyzed by three-dimensional finite element method under different load angle. Results The Von Mises stress values obtained for the remaining tissues adjacent to defect cavity were higher when rehabilitated by inferior hollow obturator in comparison with by superior hollow obturator. The maximum of Von Mises were higher when rehabilitated by resilient hollow obturator than by rigid hollow obturator. It was also observed that in the rigid type stress distribution contours formed in the remaining tissues adjacent to defect cavity, while in resilient hollow obturator prostheses the stress distributed mainly in the prosthesis itself. The oblique load shows the most maximum of Von Mises among all types of obturator prostheses. Conclusions A high lateral wall of an obturator may be more better in preserving the remaining structures than a shorter prosthesis lateral wall. A soft liner may be incorporated to reduce the pain of the residual maxillary structures and mucosa. When load on defect, higher stress would be generated to the residual maxillary structures. The adjustment of occlusual relationship is very important.
出处 《Journal of Central South University of Technology》 2005年第z1期365-368,共4页 中南工业大学学报(英文版)
  • 相关文献

参考文献2

二级参考文献8

  • 1赵铱民.再生型钴铬合金的临床应用研究[J].实用口腔医学杂志,1996,12(3):214-215. 被引量:1
  • 2Cook SD,Weinstein AM,Klawitter JJ.Parameters affecting the stress distribution around the LTI carbon and aluminum oxide dental implant[].Journal of Biomedical Materials Research.1982 被引量:1
  • 3Carter DR,Hayes WC.The compressive behavior of bone as a two-phase porous structure[].Journal of Bone and Joint Surgery British Volume.1977 被引量:1
  • 4Orr TE,Carter DR.Stress analysis of joint arthroplasty in the proximal humerus[].Journal of Orthoptera Research.1985 被引量:1
  • 5Miyasaka J,Tanne K,Tsutsumi S.Finite element analysis of the biomechanical effects of orthodontic forces on the craniofacial skeleton:Construction of a three-dimensional finite element model of the craniofacial skeleton[].Osaka-Daigaku-Shigaku-Zasshi.1986 被引量:1
  • 6Haluk I,Tekkaya AE,mer zten,et al.Biomechanical effects of rapid maxillary expansion on the craniofacial skeleton, studied by the finite element method[].European Journal of Orthodontics.1998 被引量:1
  • 7Daniel R,Lorraine O,Derek D,et al.Presurgical finite element analysis from routine computed tomography studies for craniofacial distraction: Ⅱ.An engineering prediction model for gradual correction of asymmetric skull deformities[].Plastic and Reconstructive Surgery.1998 被引量:1
  • 8Sameshima GT,Melnick M.Finite element based Cephalometric analysis[].Angle Orthodontist.1994 被引量:1