摘要
通过对回收装置和被回收制冷剂系统建立数学模型及数值计算,模拟了制冷剂回收过程中的流量变化;得出了两种环境温度、两种不同状态下制冷剂回收时的流量变化特性,并对结果进行了分析,为制冷剂回收装置的设计和性能优化提供了参考。
A mathematic model for recovery equipment and the system by that to be recovered refrigerant was derived. The model simulated the process of refrigerant's flux variety,obtained the refrigerant's flux variety characteristic on two different environment temperature and two different conditions, and analyzed the result. The result can provide references for refrigerant recovery and refrigerant pouring equipment's design and performance optimization.
出处
《制冷空调与电力机械》
2006年第6期4-7,共4页
Refrigeration Air Conditioning & Electric Power Machinery