摘要
针对给水泵启动后出现动静部件碰磨并严重损坏的问题,通过对给水泵的结构、运行参数进行深入细致的分析,找到了故障原因,并提出了解决措施。
Aiming at the problems on collision between the rotational and the quiet part and!failure seriously after feedwater pump operation,after analysis on the structure,operation data of feedwater pump,the countermeasures are brought forward.
出处
《河北电力技术》
2007年第4期40-42,共3页
Hebei Electric Power
关键词
给水泵
密封水
动静碰磨
损坏
feed water pump
sealed water
collision between rotational and quiet part
damage