期刊文献+

Study on the effect of PET/CT-guided nasopharyngeal carcinoma target delineation on the dose received by endangered organs

下载PDF
导出
摘要 Objective:To compare the differences of radiation-induced doses between 18F-FDG-PET/CT and CT/MRI-guided target delineation in nasopharyngeal carcinoma in intensity-modulated radiotherapy.Methods:A total of 31 patients with locally advanced nasopharyngeal carcinoma receiving treatment in our hospital from December 2016 to December 2017 were studied in this research,and 18F-FDG-PET/CT and CT/MRI were used to guide the target delineation to develop an intensity-modulated radiotherapy plan(experimental group and control group).The dose differences between GTV and endangered organs in the two groups were compared.Results:Comparison of primary tumor volume:PET/CT was smaller than CT/MRI,and volumes of T3 and T4 were significantly different(P<0.001).Comparison of the two delineation plans,in terms of PGTV in Dmin,Dmean,and D95,the data of experimental group was smaller than that of the control group;in Dmax,the PGTV of the experimental group was larger than that of the control group with P<0.001 considered as a significant difference.In Dmin and Dmax,doses of experimental groups of the spinal cord were lower than those of the control group,showing a significant difference(P=0.022,0.042);In Dmean,there was no difference between the two groups.In Dmax doses of an experimental group of the brainstem and parotid gland were significantly smaller than the control group(P=0.001,0.047)while there was no difference between Dmin and Dmean.There was no difference between the two groups of Dmin,Dmean,and Dmax in the doses received by chiasm and temporal lobe.Conclusion:PET/CT guided target delineation is applied in the simultaneous dose adjustment of intensity-modulated radiation therapy in patients with advanced nasopharyngeal carcinoma.In primary lesion targets shown by MRI/CT,the tumor tissue of PET/CT concentration zone was given a higher dose with relatively smaller average dose and minimum dose in the overall tumor target area.Statistics also showed that the doses received by the spinal cord,brain stem,and parotid gland were
出处 《Journal of Hainan Medical University》 2019年第15期53-57,共5页 海南医学院学报(英文版)
基金 Scientific Research Project on Health Planning(16A200048).
  • 相关文献

参考文献4

二级参考文献30

  • 1钱英.PET/CT的最新进展[J].医疗设备信息,2005,20(5):31-31. 被引量:5
  • 2房爱玲.正电子发射断层成像装置PET/CT的临床应用[J].医疗设备信息,2007,22(5):57-57. 被引量:2
  • 3Lin Q, Yang R, Sun L, et al. Biological response of nasopharyngeal carcinoma to radiation therapy: a pilot study of using serial 18F-FDG PET/CT scans. Cancer Invest, 2012,30: 528 -536. 被引量:1
  • 4MacManus M, Nestle U, Rosenzweig KE, et al. Use of PET and PET/CT for radiation therapy planning:IAEA expert report 2006- 2007. Radiother Oncol,2009,91:85-94. 被引量:1
  • 5Boellaard R. Standards for PET image acquisition and quantitative data analysis. J Nucl Med,2009,50 : 11-20. 被引量:1
  • 6Wang D, Schultz C J, Jursinic PA, et al. Initial experience of FDG-PET/CT guided IMRT of head-and-neck carcinoma. Int J Radiat Oncol Biol Phys ,2006,65 : 143-151. 被引量:1
  • 7Ford EC, Kinahan PE, Hanlon L, et al. Tumor delineation using PET in head and neck cancers:threshold contouring and lesion volumes. Med Phys,2006,33:4280-4288. 被引量:1
  • 8Burri RJ, Rangaswamy B, Kostakoglu L, et al. Correlation of positron emission tomography standard uptake value and pathologic specimen size in cancer of the head and neck. Int J Radiat Oncol Biol Phys,2008,71:682-688. 被引量:1
  • 9Daisne JF, Duprez T, Weynand B, et al. Tumor volume in pharyngolary-ngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen. Radiology,2004,233:93-100. 被引量:1
  • 10Paulino AC, Koshy M, Howell R, et al. Comparison of CT-and FDG-PET-defined gross tumor volume in intensity-modulated radiotherapy for head-and-neck cancer. Int J Radiat Oncol Biol Phys,2005,61:1385-1392. 被引量:1

共引文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部