期刊文献+

薄膜扭矩传感器栅丝结构尺寸对性能的影响 被引量:2

Influence of Structure Size of Thin Film Torque Sensor Grid Wire on Performance
原文传递
导出
摘要 对一种薄膜扭矩传感器的栅丝进行建模,从栅丝的宽度、长宽比和间距3方面对栅丝的几何尺寸进行了性能影响仿真分析。栅丝宽度、长宽比和间距影响到栅丝对基体应变的传递性能,通过建立等应变梁模型,选择合理的宽度、长宽比和间距参数,使得应变传递误差小于1%。据此分析数据设计制作了薄膜扭矩传感器,并测试了该薄膜扭矩传感器的环境适应性等性能。 One kind of grid wire of thin film torque sensor is modeled.Simulation analysis on the performance influence of grid wire’s physical dimension from three aspects of width,length-width ratio and space is carried out.The width,length-width ratio and space affect the transferability of matrix strain by grid wire.By building equal strain beam model,choosing reasonable width,length-width ratio and space parameters,the strain transfer error is controlled to less than 1%.Based on the data,a thin film torque sensor is made,and its environment adaptability and other capabilities are tested.
作者 顾凯荣 林杰俊 廖然 倪昔东 齐红丽 闫博 GU Kairong;LIN Jiejun;LIAO Ran;NI Xidong;QI Hongli;YAN Bo(Shanghai Marine Equipment Research Institute,Shanghai 200031,China;Department of Micro/Nano Electronics,Shanghai Jiao Tong University,Shanghai 200240,China)
出处 《船舶工程》 CSCD 北大核心 2021年第S01期295-298,共4页 Ship Engineering
关键词 薄膜 扭矩 传感器 栅丝 结构尺寸 thin film torque sensor grid wire structure size
  • 相关文献

参考文献5

二级参考文献15

  • 1蔡琪,曹春斌,江锡顺,宋学萍,孙兆奇.ITO薄膜的微结构表征及其组分特性[J].真空科学与技术学报,2007,27(3):195-199. 被引量:23
  • 2强锡富.传感器[M].北京:机械工业出版社,1998.. 被引量:11
  • 3Shang Weilu, Dai Ming, Yah Kongping, Qian Zhaojun. THE SYSTEM FOR MEASURING AND TESTING THE SHAFT TORSION [ A ]. APMF2003/IMEKO TC3 [ C ]. Shanghai, 2003. 被引量:1
  • 4Shang Weilu, Chen Yongpei, Wang Yah, Li Tao. 2000kNm TORQUE STANDARD MACHINE [ A]. APMF2000[ C]. Japan, 2000. 被引量:1
  • 5.EA Guidelines on the Calibration of Static Torque Measuring Devices[].EA-/.2000 被引量:1
  • 6唐文彦.传感器[M].第四版.北京:机械工业出版社,2007. 被引量:1
  • 7颜重光.薄膜应变式传感器及其优点[J].中国仪器仪表,1984,8(4):50-53. 被引量:1
  • 8LEI J F, WILL H A, MARTIN L C. Thin film sensorsfor minimally-intrusive measurements in harsh high temperature environments [ C ]. 34th AIAA/ASME/SAE/ ASEE Joint Propulsion Conference and Exhibit, Joint Propulsion Conferences, 1998:3610. 被引量:1
  • 9AONO H, SHINOHARA J, CHIKATA T,et al. Thin filmgauges for measuring dynamic strain of acompressor blade [ C ]. Proceeding of the SEM Spring Conference on Experimental Mechanics : Las Vegas, 1985:237-243. 被引量:1
  • 10KAYSER P, GODEFROY J C, LECA L. High temperature thin film strain gauges [ J ]. Sensors and Actuators A : Physical, 1993, 37-38 (93) : 328-332. 被引量:1