期刊文献+

R32房间空调器高频制冷运行系统特性分析 被引量:1

Analysis on the characteristics of high frequency operation system of room air conditioner in R32 refrigerant
下载PDF
导出
摘要 房间空调器两器结构日渐紧凑,同时对制冷能力需求提高,通过分析制冷剂热物性,合理调试并设定制冷系统参数以确保空调器能最大发挥其制冷能力并可靠运行至关重要。从理论及实验分析R32制冷剂房间空调器处于高频输出时系统运行特性随室外侧风量变化情况,风量变化影响系统压力及制冷剂流量变化,外侧风量过大会引起蒸发温度低且过热,蒸发器内部分面积均为过热气体,有效换热面积变小,系统制冷能力下降。在实际制冷系统设计调试时,需要根据室内蒸发器进出口温差合理调节,以达到系统运行最优。 The structure of the heat exchanger of the room air conditioner is becoming more and more compact.At the same time,the demand for the refrigeration capacity is increasing.It is very important to ensure that the air conditioner can give full play to its refrigeration capacity and operate reliably by analyzing the thermal properties of the refrigerant,reasonably adjusting and setting the parameters of the refrigeration system.Theoretically and experimentally analyzes the change of system operation characteristics with outdoor air volume when the room air conditioner in R32 refrigerant is at high frequency output.The change of air volume affects the change of system pressure and refrigerant flow.Excessive external air volume causes low evaporation temperature and overheating.Part of the area in the evaporator is superheated gas,the effective heat exchange area becomes smaller,and the refrigeration capacity of the system decreases.In the actual design and commissioning of the refrigeration system,it is necessary to adjust the temperature difference between the inlet and outlet of the indoor evaporator reasonably to achieve the optimal operation of the system.
作者 高浩 戚文端 张秋朋 张浩 GAO Hao;QI Wenduan;ZHANG Qiupeng;ZHANG Hao(GD Midea Air Conditioning Equipment Co.,Ltd.,Foshan 528311)
出处 《家电科技》 2020年第4期77-79,共3页 Journal of Appliance Science & Technology
关键词 R32房间空调器 高频运行 系统特性 Room air conditioner in R32 refrigerant High frequency operation System characteristics
  • 相关文献

参考文献4

二级参考文献29

  • 1李炅,张秀平,贾磊,吴俊峰.R32管内流动传热特性的分析与讨论[J].流体机械,2012,40(12):74-79. 被引量:15
  • 2Dang C, Saitoh S, Nakamura Y, et al. Boiling heat Transfer of HFO-1234yf Flowing in Smooth Small- Diameter Horizontal Tube [C]//2010 International Sym- posium on Next-Generation Air Conditioning and Refrig- eration Technology. Tokyo: Japan, 2010, NS 21. 被引量:1
  • 3Saitoh S,Daiguji H, Hihara E. Correlation for Boiling Heat Transfer of R-134a in Horizontal Tubes Including Effect of Tube Diameter [J]. Int J Heat Mass Transfer, 2007, 50:5215-5225. 被引量:1
  • 4Stefan S B, Eckhard A G, Suresh V G. A Composite Heat Transfer Correlation for Saturated Flow Boiling in Small Channels [J]. International Journal of Heat and Mass Transfer, 2009, 52:2110-2118. 被引量:1
  • 5Jee Young Shin,Min Soo Kim,Sung Tack Ro. Experimental study on forced convective boiling heat transfer of pure refrigerants and refrigerant mixtures in a horizontal tube[J].International Journal of Refrigeration-Revue Internationale du Froid,1997.267-275. 被引量:1
  • 6Dongsoo Jung,Kwangyong An,Jinseok Park. Nucleate boiling heat transfer coefficients of HCFC22,HFC134a,HFC125,and HFC32 on various enhanced tubes[J].International Journal of Refrigeration-Revue Internationale du Froid,2004.202-206. 被引量:1
  • 7Anowar Hossain Md,Onaka Yoji,Akio Miyara. Experimental study on condensation heat transfer and pressure drop in horizontal smooth tube for R1234ze(E),R32 and R410A[J].International Journal of Refrigeration-Revue Internationale du Froid,2012. 被引量:1
  • 8Wang H S,Rose J W,Honda H. Condensation of refrigerants in horizontal micro-fin tubes:comparison of correlations for frictional pressure drop[J].International Journal of Refrigeration-Revue Internationale du Froid,2003.461-472. 被引量:1
  • 9Marko Matkovic,Alberto Cavallini,Davide Del Col. Experimental study on condensation heat transfer inside a single circular mini-channel[J].International Journal of Heat and Mass Transfer,2009.2311-2323. 被引量:1
  • 10Cavallini A,Censi G,Del Col D. Rossetto.Experimental investigation on condensation heat transfer and pressure drop of new HFC refrigerants (R134a,R125,R32,R410A,R236ea) in a horizontal smooth tube[J].International Journal of Refrigeration-Revue Internationale du Froid,2001.73-87. 被引量:1