对灭火器配置设计中遇到的7个问题进行分析和总结:灭火器设置位置的合理性、较低危险级场所配置较高级别灭火器、灭火器的最大保护距离的判定依据、地库配置推车式灭火器、住宅建筑灭火器配置、备用灭火器、汽车库的灭火器配置场所火灾种类。
7 issues when designing fire extinguisher distribution encounters were discussed in this paper,these 7 issues include:the location reasonability of fire extinguisher distribution;higher rating fire extinguisher in lower fire rating place;judgement base of fire extinguisher’s maximum travel distance;wheeled fire extinguisher distributing in under ground garage;residence fire extinguisher distribution;standby fire extinguisher;fire type of the fire extinguisher distribution place of garage.Meanwhile,this paper puts forward some problems in associated active codes.
作者
张可
Zhang Ke(China Aviation Changsha Design and Research Institute Co.,Ltd.,Changsha 410014,China)
出处
《给水排水》
CSCD
北大核心
2020年第S01期818-820,共3页
Water & Wastewater Engineering
关键词
灭火器
配置
探讨
Fire extinguisher
Distribution
Discussion